C) FLEXIBLE HOSE INSTALLATION
1) Install flexible hoses onto hot and cold water outlets.
2) Secure hoses with wrench. Do not over tighten.
3) Connect flexible hoses to supply tee.
4) Circle the excessive part of hoses as shown in figure below .
F) INSTALLATION CHECKOUT
1) Ensure all connections are tightened properly.
2) Turn on main water supply.
3) Turn on and off cold and hot water respectively.
4) Turn on both hot and cold water and turn off. Check for leaks.
5) Remove the aerator with attached key. Check for debris. Clean of necessary.
6) Reinstall aerator.
COMPLETE INSTALLATION
MODEL: F2-0014
E) SUPPLY CONNECTION
1) Install lavatory according to manufacturers instructions.
2) Connect hoses (not provided) to angle stops.
3) Tighten all connections.
*** VERY IMPORTANT ***
4) Flush out water for two minutes before connect hose to faucet valve.
(This act to avoid debris trapped the flow regulator)
D) DRAIN WASTE INSTALLATION
1) Disassemble the drain.
2) Apply plumbers putty or sealant to bottom side of flange.
(Or use attached rubber washer to instead of putty)
3) Insert drain body through sink.
4) Attach the gasket, Teflon washer and tighten the lock nut.
5) Apply Teflon tape to the drain pipe threads and screw with drain body
6) Remove excessive plumbers putty or sealant.