® Owner's Manual This Manual is for the Installation, Operation, and Maintenance of the ® WATER FACTORY SYSTEMS FaucetMATE Drinking Water Appliance © 2002 CUNO Incorporated 98-91121 0902
INTRODUCTION This manual explains the installation, operation and maintenance of the Water Factory Systems’ FaucetMATE® Drinking Water Appliance. Please read each section of this manual carefully. The specific model chosen should be appropriate for the local water conditions and the customer’s needs. Check the Performance Data Sheet for the performance characteristics and the conditions of use.
Congratulations and thank you for purchasing the Water Factory Systems’ FaucetMATE® Drinking Water System. You are about to enjoy the benefits of high quality drinking water right in your own home. The FaucetMATE dual-stage filtration systems contain the most effective filtration media for reducing common but potentially harmful pollutants.
F. Make the faucet mounting hole Procedure: 1) Mark the center for the 9/16" hole. 2) Form a shallow putty dam around the hole area and fill it with enough water to lubricate the carbide drill bit. 3) Carefully drill a pilot hole through the porcelain/enamel and the base metal using a carbide type pilot drill. Important: Always operate the drill with light pressure at a slow speed (300-400 rpm). 4) Insert the pilot tip of the spring-loaded porcelain cutter into the pilot hole.
I. Installing the feed water valve J. Make tubing connections The saddle tapping valve which is supplied is designed to be used on 3/8” - 1/2” OD soft copper tubing (plain or chromed) and rigid metal pipe. Do not use with flexible ribbed tubing because it requires special hardware. Optional feed valves should be used for this purpose. NOTE: With all of the components in place, the tubing connections can be made. Be sure to arrange the tubing so that there are no sharp bends.
Figure 1 Faucet Feedwater Valve FM-2 & FM-2 Lead Plus Figure 2 Rubber Washer Chrome Base Plate Rubber Washer Plastic Bottom Washer Star Washer Hex Nut 6
Figure 3 Valve Handle Stem Nut/Seal Piercing Lance Insert Plastic Sleeve Compression Nut 1/4" Orange Feedwater Tubing For 3/8" OD tubing, use the side of the bracket with the projections. For 7/16" to 1/2" OD tubing or rigid pipe, use the "V" side of the bracket. Figure 4 ‘Push-In’ Tubing Connector This product is outfitted with user friendly ‘Push In’ connectors. Proper use of the connectors is shown in the diagrams.
Figure 5 To Faucet Outlet Fitting with Flow Control Feedwater Inlet 47-55711G2 47-55707G2 47-55707G2 From Feedwater Source FM-350 DWS NOTE: Some state and local plumbing codes may prohibit the use of saddle-type valves and/or drain connections. The use of saddle-type valves are prohibited in: Alaska, Delaware, Idaho, Kentucky, Massachusetts, Michigan, Minnesota, New Hampshire, North Dakota, Ohio, Oregon, and South Dakota. Check your local plumbing codes for any restrictions that may apply.
CUNO Incorporated 400 Research Parkway Meriden, CT 06450, U.S.A. Toll Free: 1-800-733-1199 Worldwide: 203-237-5541 Fax: 203-238-8701 www.waterfactorysystems.com • www.cuno.