Owner`s manual
ORP OVERFEED TIMEOUT:
The ORP Overfeed Timeout inhibits ORP feed, activates audible and visual alarms,
and sends a message to the POOLCOMM website when the ORP setpoint is not
reached after feeding continuously for a selectable period of time.
From the Configuration Setup Menu:
Press DOWN to find the ORP Overfeed Timeout menu item.
Press ENTER to select ORP Overfeed Timeout.
The current ORP Overfeed Timeout Setting will be displayed:
Press UP or DOWN to scroll to the desired setting.
Press ENTER to save your selection.
AUXILIARY pH SETPOINT:
The auxiliary relay can be programmed to provide acid or base feed pH correction,
or to support supplemental pH control with a second setpoint. Once the setpoint is
entered, go to Auxiliary Output Setup to assign the relay to the desired function.
From the Configuration Setup Menu:
Press DOWN to find the Auxiliary pH Setpoint menu item.
Press ENTER to select Auxiliary pH Setpoint.
The current Auxiliary pH Setpoint will be displayed:
Press UP or DOWN to scroll to the desired setting.
Press ENTER to save your selection.
AUXILIARY ORP SETPOINT:
The auxiliary relay can be programmed to support supplemental ORP control with a
second setpoint, or dechlorination. Once the setpoint is entered, go to Auxiliary
Output Setup to assign the relay to the desired function.
From the Configuration Setup Menu:
Press DOWN to find the Auxiliary ORP Setpoint menu item.
Press ENTER to select Auxiliary ORP Setpoint.
The current Auxiliary ORP Setpoint will be displayed:
Press UP or DOWN to scroll to the desired setting.
Press ENTER to save your selection.
AUX pH Setpoint
7.5 pH
ORP Overfeed Timeout
Off
AUX ORP Setpoint
650 mV