SECTION 10. MAINTENANCE
CAT 4000 CONTROLLER PACKAGE
The CAT 4000 controller unit is virtually maintenance free. Cleaning of the
enclosure, front panel and flow cell can be performed using a clean, soft cloth
moistened with mild soap and water solution or glass cleaner. Use of abrasives or
harsh chemicals may damage the enclosure and membrane switch panel.
WATER MAINTENANCE
Always test and record water chemistry readings in compliance with Health
Department requirements using a quality manual test kit. Calibrate pH periodically
as described earlier in this manual.
It is important to note that changes in pH, cyanuric acid concentration, total
dissolved solids, and use of additional or alternative sanitizers will all affect the
primary sanitizer residual level relative to ORP. It is important to maintain total
alkalinity on a regular basis to ensure pH stability. To maintain a consistent sanitizer
residual in parts-per-million (ppm), periodically adjust the ORP setpoint.
PRECISION CALIBRATION
The CAT 4000 controller provides instrument-grade accuracy which exceeds that of
most liquid-standard water testing kits. Therefore, it may be preferable to calibrate
pH using commercially available reference solutions.
SENSOR MAINTENANCE
The sensors must be clean and free from oil, chemical deposits and contamination to
function properly. After saturation in pool or spa water, the sensors may need to be
cleaned on a weekly or monthly basis depending on bather load and other facility-
specific characteristics. Slow response, increased need to calibrate pH, and
inconsistent readings are indications that the sensors are in need of cleaning.
To clean the sensors, disconnect from the controller and carefully remove them from
the flow cell. Clean the reference junction (the white teflon ring at the bottom of
sensor body) with a soft tooth brush and regular tooth paste. A household liquid
dishwashing detergent may also be used to remove any oil. Rinse with fresh water,
replace teflon thread-seal tape, and reinstall sensors.
SENSOR REPLACEMENT
CAT Professional Series pH and ORP sensors are engineered to provide the highest
performance and longest possible functional service life. If properly cleaned
sensors provide unstable readings or require excessive calibration, the pair of
sensors should be replaced. For optimum controller performance, replace with
genuine CAT Professional Series sensors PRO15-2 and PRO25-2.