The PrimeLab 2.0 hardware-development and design, the
firmware, software, app and cloud-solution, along with all
calibration curves (parameters) and reagents are entirely
Made in Germany.
4 x 24mm/10ml glass vials with lid (light shield integrated in lid)
1 x 24mm vial adapter (built-in; exchangeable)
1 x Battery-Charger with USB-cable (type C)
Item code Item description
PrimeLab 2.0 Basic Kit
PL02B PrimeLab 2.0 Basic Kit in plastic carrying case with foam insert.
1 x PrimeLab 2.0 Multitest Photometer
1 x light shield for 16mm vials, Eppendorf vials and calibration
1 x 10.5 cm plastic stirring rod
1 x graduated 10ml plastic syringe
1 x vial cleaning brush
18 19
© Water-i.d. GmbH / Germany
lab-pipettes, filter equipment or additional vials.
on the parameter-methods chosen, additional equipment may be needed, such as professional
Although the PrimeLab 2.0 Basic-Kit already contains most of the accessories needed, depending
PrimeLab 2.0 Accessories
Technical Data
Legipid (1 hour Legionella test) requires special equipment, which is not listed on this page
PL2Sp-IH40ATC-ALK pH-Electrode ("Low Sodium Error" version).
PLSp2-USBhuba USB-Hub (Type C and Type A)
Electrodes / Probes
BNC-connector, cable length = 1 meter.
PLSp2-USBcable USB-cable (Type A on one end / type C at the other end)
Other Accessories
Reference standards
PL2Sp-IJ44A/ATC pH-Electrode for solids: Soils, creams, emulsions, foods.
® ®
PLSp-BltD-1 Bluetooth USB dongle (to enable Bluetooth on any Windows-PC)
PLSp2-carr2 Large PrimeLab 2.0 plastic carrying case
PLSp2-Ad16/Ad1 PrimeLab 2.0 vial adapter for 16mm glass vials / 1ml Eppendorf vials
reasonable ionic strength. BNC-connector, cable length = 1 meter.
BNC-connector, cable length = 1 meter.
PLSp2-USBa-c USB-connector (type A to type C)
Ask for our large variety of check-standards (coloured epoxy raisin) in sealed 24mm glass
vials
PLSp-mft-1 Micro fiber cloth 13x13 cm for PrimeLab vials
Sealed gel electrode for samples with low contamination levels and
PL2Sp-Ref112038-f Reference standard kit for PrimeLab IDs 11 (chlorine by tablet), ID
20 (cyanuric acid) and ID 38 (pH by tablet).2 standards for ID 11
(~0.5 mg/l and ~2 mg/l), 1 standard for ID 20 (~80 mg/l), 1 standard
for ID 38 (~7.00 pH) as well as a ZERO vial.
PLSp2-chargeEU PrimeLab 2.0 charger with EU plus
PLSp2-GSM GSM-modem (USB-Type-C)
PLSp2-UK/AUS/US UK/AUS/US plug for PrimeLab 2.0 charger
PL2Sp-Ref122039-f Reference standard kit for PrimeLab IDs 12 (chlorine by liquid), ID 20
(cyanuric acid) and ID 39 (pH by liquid).
PL2Sp-RefFLSC 2 x 100ml reference standards 100 µg/l Fluorescein, deionized water
PL2Sp-RefTRB 3 x 10ml reference standards 0.5 NTU, 10 NTU, 1000
PL2Sp-IH40ATC pH-Electrode
Sealed gel electrode for samples with low contamination levels and
PL2Sp-RefPTSA 2 x 100ml reference standards 500 µg/l PTSA, deionised water
reasonable ionic strength. BNC-connector, cable length = 1 meter.
2 standards for ID 12 (~0.5 mg/l and ~2 mg/l), 1 standard for ID 20
(~80 mg/l), 1 standard for ID 39 (~7.00 pH) as well as a ZERO vial.
In a box with description. 1 year shelf life.
PL2Sp-IJ44A pH-Electrode for solids: Soils, creams, emulsions, foods.
PLSp2-Alucase Aluminium trolley with foam inserts for PrimeLab 2.0 plus accessories
In a box with description. 1 year shelf life.
PLSp-GlsBot50ml 50ml glass-bottle with stopper
PLSp-Kv1610-10 Set of 10 x 16mm (10ml) round glass vials with lid
Vials and measuring cups
PLSp-Kv1-100 Set of 100 x 1ml Eppendorf-vials
Item code Item description
SVZdev100 100ml plastic measuring cup
PLSp-Kv2410-10 Set of 10 x 24mm (10ml) round glass vials with lid / light shield
integrated in lid
PLSp-PIP01ml-tips10 10 x tips for PLSp-PIP01ml pipette
PLSp-LG-ELF10 Set of 10 x 60ml measuring cup with red lid
PLSp-inj01 Graduated Plastic Syringe (1ml)
PLSp-PIP10ml-tips10 10 x tips for PLSp-PIP10ml pipette
PLSp-PIP1ml 1 ml pipette (variable volume 0.1-1ml)
PLSp-PIP01ml 0.1 ml pipette (variable volume 0.01-0.1ml)
Filter utilities
PLSp-InjFil-1 Luer lock syringe (20ml) with threat for filter holder
PLSp-FiltGFC 25mm GF/C Filter. Bottle of 50 filter papers
PLSp-Filt45M 25mm 0.45 µm filter. Bottle of 50 filter papers
PLSp-inj03 Graduated Plastic Syringe (3ml)
PLSp-PIP10ml 10 ml pipette (variable volume 1-10ml)
SPstr10 Set of 10 x 13 cm plastic stirring rods
Dosing equipment
PLSp-str10 Set of 10 x 10.5 cm plastic stirring rods
Electronics
PLSp-CODheatblock-E Heat block for 8 x 16mm vials. Temp. 70, 100, 120, 150 and
160°C. Digital reading,
Stirring rods / cleaning brushes
220 - 240 V / 50 - 60 Hz and 110 - 130 V / 50 – 60 Hz, 140W
PLSp-Filtad1 filter holder for PLSp-InjFil-1 luer lock syringe
SPclb10 Set of 10 x 9.5 cm vial-cleaning brushes
Digital reading. 230V, 50/60 Hz.
PLSp-CODheatblock-L Single block thermostat for 12 x 16mm vials. Temperature up
to 150°C.
PLSp-inj1 Graduated Plastic Syringe (10ml)
PLSp-PIP1ml-tips10 10 x tips for PLSp-PIP1ml pipette
Display: 5.5'‘ Color-HD-Touch Display
Camera: In-built barcode / QR-code scanner
Individual adjustment possible
test instructions during measurement process
Power supply: 8,500 mA Li-Io-battery
Water-proof rating: The device is splash-water-proof (IP )ausfüllen
Calibration: Auto-calibration function with certificate (software)
Internal memory: >5,000
with recognition of ZERO types
(software) LabCOM App (Android / iOS)
Clock/Date: RTC (Real-Time-Clock) with calendar function
Using reagents from other manufacturers may lead
to wrong readings / higher tolerances PrimeLab reagents
are etirely “Made in Germany” or “Made in UK”!
Reagents: The calibration curves for the individual parameters /
measurement procedures are adjusted to the reagents
offered by Water-i.d.
LabCOM Cloud (web-browser)
Languages: > 15
Auto-Off: Factory default setting = 10 minutes.
One-Time-Zero: Intelligent OTZ (One-Time-Zero) function
Environment: 5°C - 45°C / 30 - 90% rel. humidity
Menu guidance: Intuitive, display-controlled 4-button menu guidance;
Electrodes: USB-type-C connector for pH/EC/TDS/ORP/Temp-Probes
User defined parameter function
®
Connectivity: Bluetooth 4.2
GSM (via USB-modem)
585/610/645/680/705/730/760/810/860/900/940nm
Connectivity: LabCOM software (Windows / Mac)
Spectral range: 390nm - 950nm
180° and 90° Setup for direct and indirect measurement
Weight: 715g
(technical) WiFi
USB (type C)
Dimensions: 10cm x 25.5cm x 5.9cm (width x length x depth)
18 wavelength, peaks at 410/435/460/485/510/535/560/
Parameters: more than 140 parameters (flexible setup)
Probe-Accessories
Item code Item description
.PL2Sp-IH30D ORP-Electrode with Pt-disc for faster response.
PL2Sp-IH30 ORP-Electrode.
BNC-connector, cable length = 1 meter.
PL2Sp-EC1T EC-Electrode (2-pole).
BNC-connector, cable length = 1 meter. ATC
PL2Sp-ElBox PrimeLab 2.0 Electrode-Connector (A/D switch)
Other
reasonable
ionic strength. BNC-connector, cable length = 1 meter.
PL2Sp-Probe-Holder PrimeLab 2.0 Electrode-Holder
Sealed gel electrode for samples with low contamination levels and
PL2Sp-Probe-Stirrer PrimeLab 2.0 magnetic-stirrer
Calibration / Reference Standards
User manual
User manual
1 x "PL2Sp-KCl3mol-10" dropper bottle with 10ml KCl-electrode soaking
solution
1 x "EMphbuf1000-20" 20 ml "pH 10.00" calibration solution
1 x "EMphbuf400-20" 20 ml "pH 4.00" calibration solution
PL2SP-ElePHsolids PrimeLab 2.0 Electrode-Basic-Kit "pH (solids)":grey carrying case with
foam insert
PL2SP-ElePHlowSodKit PrimeLab 2.0 Electrode-Basic-Kit "pH (low sodium error)":grey carrying
case with foam insert
Measuring range: 0.00 - 14.00 pH, resolution: 0.01 pH
1 x "PL2Sp-ElBox" A/D-switch-box with BNC-IN and USB-Type-C-OUT to
connect with PrimeLab 2.0 Photometer
1 x "EMphbuf700-20" 20 ml "pH 7.00" calibration solution
1 x "EMphbuf1000-20" 20 ml "pH 10.00" calibration solution
1 x "PL2Sp-IJ44A" pH-Electrode for solids: Soils, creams, emulsions,
foods. BNC-connector, cable length = 1 meter Measuring range: 0.00 -
14.00 pH, resolution: 0.01 pH
Kits
1 x "EMphbuf700-20" 20 ml "pH 7.00" calibration solution
1 x "EMphbuf400-20" 20 ml "pH 4.00" calibration solution
PL2SP-ElePHkit PrimeLab 2.0 Electrode-Basic-Kit "pH / Temp.": grey carrying case with
foam insert 1 x "PL2Sp-IH40ATC" pH-Electrode. Sealed gel electrode for
samples with low contamination levels and reasonable ionic strength. BNC-
connector, cable length = 1 meter. Measuring range: 0.00 - 14.00 pH,
resolution: 0.01 pH; Temperature-range: 0 - 60°C. ATC 1 x "PL2Sp-ElBox"
A/D-switch-box with BNC-IN and USB-Type-C-OUT to connect with
PrimeLab 2.0 Photometer 1 x "PL2Sp-KCl3mol-10" dropper bottle with 10ml
KCl- electrode soaking solution 1 x "EMphbuf700-20" 20 ml "pH 7.00"
calibration solution 1 x "EMphbuf400-20" 20 ml "pH 4.00" calibration
solution 1 x "EMphbuf1000-20" 20 ml "pH 10.00" calibration solution
1 x "PL2Sp-KCl3mol-10" dropper bottle with 10ml KCl-electrode soaking
solution
1 x "EMphbuf400-20" 20 ml "pH 4.00" calibration solution
PL2SP-ElePHsolidsATC PrimeLab 2.0 Electrode-Basic-Kit "pH (solids) + Temp. (ATC)":
grey carrying case with foam insert
various ask for our full list of calibration standards
1 x "PL2Sp-ElBox" A/D-switch-box with BNC-IN and USB-Type-C-OUT to
connect with PrimeLab 2.0 Photometer
User manual
1 x "PL2SP-IJ44A/ATC " pH-Electrode for solids: Soils, creams,
emulsions, foods. BNC-connector, cable length = 1 meter. With
Temperature-reading and ATC.
Measuring range: 0.00 - 14.00 pH, resolution: 0.01 pH
1 x "PL2Sp-IH40ATC-ALK" pH-Electrode ("Low Sodium Error" version).
Sealed gel electrode for samples with low contamination levels and
reasonable ionic strength. BNC-connector, cable length = 1 meter.
1 x "PL2Sp-ElBox" A/D-switch-box with BNC-IN and USB-Type-C-OUT to
connect with PrimeLab 2.0 Photometer
1 x bottle with reference electrolyte
1 x bottle with reference electrolyte
User manual
1 x "PL2Sp-KCl3mol-10" dropper bottle with 10ml KCl-electrode soaking
solution
1 x "EMphbuf700-20" 20 ml "pH 7.00" calibration solution
1 x "EMphbuf1000-20" 20 ml "pH 10.00" calibration solution
1 x "EMorpbuf468-20" 20 ml "ORP +468mV" calibration solution
1 x "EMorpbuf220-20" 20 ml "ORP +220mV" calibration solution
1 x "PL2Sp-IH30" ORP-Electrode. Sealed gel electrode for samples
with low contamination levels and reasonable ionic strength. BNC-
connector, cable length = 1 meter. Measuring range: +/- 1,000mV,
resolution: 1mV
1 x "PL2Sp-ElBox" A/D-switch-box with BNC-IN and USB-Type-C-OUT
to connect with PrimeLab 2.0 Photometer
TDS: 0 - 2000 mg/l (1 mg/l), 2 - 325 g/l (1 g/l)
1 x "PL2Sp-KCl3mol-10" dropper bottle with 10ml KCl-electrode
soaking solution
PL2SP-EleORPkit PrimeLab 2.0 Electrode-Basic-Kit "ORP":grey carrying case with foam
insert
User manual
PL2SP-EleORPptdisckit PrimeLab 2.0 Electrode-Basic-Kit "ORP / Pt-disc for faster response":
1 x "EMorpbuf220-20" 20 ml "ORP +220mV" calibration solution
User manual
1 x "PL2Sp-EC1T" EC-Electrode (2-pole). BNC-connector, cable length =
1 meter. ATC
Measuring range: +/- 1,000mV, resolution: 1mV
1 x "PL2Sp-ElBox" A/D-switch-box with BNC-IN and USB-Type-C-OUT to
connect with PrimeLab 2.0 Photometer
Measuring range / resolution:
1 x "EMorpbuf468-20" 20 ml "ORP +468mV" calibration solution
1 x "PL2Sp-ElBox" A/D-switch-box with BNC-IN and USB-Type-C-OUT to
connect with PrimeLab 2.0 Photometer
EC: 0 - 2000 µS/cm (1 µS/cm), 2 - 500 mS/cm (1 mS/cm)
1 x "EMecbuf1413-20" 20 ml "1413 µS/cm" calibration solution
PL2SP-EleECkit PrimeLab 2.0 Electrode-Basic-Kit "EC-TDS-Salz / Temp.": grey carrying
case with foam insert
1 x "EMecbuf1288-20" 20 ml "12.88 mS/cm" calibration solution
User manual
PL02B-TRB PrimeLab 2.0: Starter-Kit WITH Turbidity (NTU) (without reagents)
Temperature: 0 - 90°C (1°C)
1 x grey plastic carrying-case with foam insert
4 x 24mm/10ml glass-vials with lid (light-shield incorporated into the lid)
grey carrying case with foam insert
1 x "PL2Sp-IH30" ORP-Electrode with Pt-disc for faster response. BNC-
connector, cable length = 1 meter.
1 x PrimeLab 2.0 Multitest Photometer
Salt: 0 - 1000 mg/l (1 mg/l), 1.00 - 300 g/l (1 g/l)
compatible to the free of charge PrimeLab tools: LabCOM App/Software/Cloud
(Android, iOS, Windows, Mac, Browser)
1 x 10ml syringe
1 x NTU-Turbidity calibration kit. Sealed glass vials with 0.5 / 10 / 1000
1 x Bluetooth USB dongle
1 x microfibre cleaning cloth for vials
1 x grey plastic carrying-case with foam insert
NTU
USB Type C
1 x charger with cable (USB-Type-C)
PL02BALL PrimeLab 2.0: starter-kit / ALL parameters activated (without reagents)
1 x vial cleaning brush
built-in camera to scan QR-Codes
1 x 24mm vial adapter (built-in; exchangeable)
Self-Calibration-Mode with certificate (via LabCOM software)
1 x light shield (for 16mm and 1ml vials as well as check-standards)
10 x 24mm/10ml glass-vials with lid (light-shield incorporated into the lid)
1 x light shield (for 16mm and 1ml vials as well as check-standards)
5.5'' HD-Colour-Touch Display
1 x 1 - 10ml professional lab pipette with 2 tips
GSM (via USB-Type-C Modem)
1 x 24mm vial adapter (built-in; exchangeable)
1 x 16mm vial adapter
2 x 10,5 cm stirring rod
1 x Filteradapter for 20ml Luer-Lock-Spritze
1 x 10ml plastic syringe (graduated)
1 x printed user manual in a ring-binder
Bluetooth 4.2
16 wavelengths-scan (410 - 940nm)
1 x PrimeLab 2.0 Multitest Photometer
"I-OTZ" Intelligent-One-Time-Zero
1 x charger with cable (USB-Type-C)
8.400 mAh Li-Ion-battery (built-in)
1 x 10.5 cm stirring rod
WiFi
Option of over 140 different parameters (chargeable activation required)
"90° ready" for NTU, PTSA, Fluorescein, Plankton
Option to connect Electrodes (via USB Type C plus A/D-changer-Box)
1 x 1ml Eppendorff-vial adapter
1 x Luer lock syringe (20ml) with adapter for filter holder
1 x can with 50 Filterpapieren GF/C (25mm)
1 x can with 50 Filterpapieren 0.4µ (25mm)
1 x Bluetooth USB dongle
1 x cleaning brush for vials
1 x 100ml can with Deckel (for dilution)
1 x microfibre cleaning cloth for vials