Instructions / Assembly
1. Fill the system and Pressure Tank until pumps cut
off.
2. Open one or more xture to drain the Pressure
Tank.
3. If there is a momentary pause in the water ow
from the time the
Pressure Tank is emptied and the pump starts,
adjust pump cut in setting clockwise slightly.
4. Close xtures and rell Pressure Tank to pump cut
off. Check time to ll.
5. Open xtures and see if pause in water is
eliminated. If not, continue adjusting pressure switch.
CALIFORNIA PROPOSITION 65 WARNING!
This product contains a chemical known by the State
of California to cause cancer and to cause birth de-
fects or other reproductive harm. (California Installer/
Contractor California law requires that this notice be
given to consumer/end user of this product.) For more
information: www.wilo-usa.com
Periodically Safety Inspection
The Pumping Piping System and Pressure Tank require safety
inspec- tion every 6 months by a licensed professional.
Customer Self-Check Sheet
Please keep this sheet and provide with Warranty Claim
Date of Inspection Professional Sign Up
3
For parts or assistance, call WATER SOURCE Customer Service at 1-877-326-3561
APPLICATIONS
Designed for water storage, pressure boosting, and water transfer.
SPECIFICATIONS & PERFORMANCE
Connection Tank Factory Max. Max.
Model Size Volume Precharge Pressure Temp
EFT20V 1” FNTP 20 Gal. 30 P.S.I. 150 P.S.I 195 F
EFT32V 1” FNTP 32 Gal. 30 P.S.I. 150 P.S.I 195 F
EFT44V 1-1/4” FNTP 44 Gal. 30 P.S.I 150 P.S.I 195 F