/2 HP GENERAL PURPOSE WATER TRANSFER PUMP MODEL: WSTPC50 D A B B C PACKAGE CONTENTS Part Description Quantity A Priming port plug 1 B 3/4” NPT x 3/4” garden hose fitting 2 C Pump 1 D Suction strainer 1 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-346-7611, 8 a.m. – 5 p.m., EST, Monday – Friday. PERFORMANCE AT 10 FT. LIFT USING 3/4” HEAVY DUTY GARDEN HOSE Discharge height above pumping level (head) 5 ft. 10 ft.
SPECIFICATIONS Power supply required ................................................................................................. 115V, 60 HZ Water temperature range .................................................................................... Max. 113°F (45°C) Individual branch circuit required ......................................................................... 15 Amp minimum Operating water depth – beginning minimum.........................................................................
CAUTION: • • • • This transfer utility pump is designed for portable applications. It can drain or remove water from the following: fish tanks, water heaters, pits, sinks, window wells, basements, swimming pool covers, boats, low spots in yards, or other flooded areas. It can also be used for temporary pressure boosting for washing cars, washing boats, or cleaning off driveways. This pump is not designed to function as a permanently installed pump.
PREPARATION WARNING: Always use handle to lift pump. Never use power cord to lift pump. To avoid skin burns, unplug and allow time for the pump to cool after periods of extended use. Estimated Assembly Time: 5 minutes Materials Required for Assembly (not included): Thread tape, 3/4 in. heavy duty garden hose (for suction), 3/4 in.
2. Use the strainer (D) when pumping from a creek, pond, or source where debris may be sucked into the pump. The strainer should prevent debris from entering the inlet line (2). Note: To prevent re-priming during periods of frequent stopping and restarting of the pump (C), install a foot valve (sold separately) instead of the included suction strainer (D). The foot valve will keep the pump primed when it is turned off. Caution: Even when using a foot valve, do not leave the pump permanently installed.
OPERATING INSTRUCTIONS – TRANSFERRING WATER WARNING: This unit is not waterproof or weatherproof and is not intended to be used in showers, saunas, or other potentially wet locations. The motor is designed to be used in a clean, dry location with access to adequate cooling air. Ambient temperatures around the motor should not exceed 104˚F (40˚C). 1. Prime and run the pump: Note: The pump must be filled with water before operation.
CARE AND MAINTENANCE DANGER: Risk of electric shock. Always disconnect the electrical supply before attempting to install, service, or perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock. Only qualified electricians should repair this unit. Improper repair could result in fatal electrical shock.
TROUBLESHOOTING Problem Possible Cause Corrective Action Pump does not 1. Blown fuse/tripped breaker 1. Replace fuse or reset breaker start or run 2. Low voltage 2. If using extension cord, use heavier gauge and shorter cord. 3. Worn motor brushes 3. See care and maintenance section 4. Blocked impeller 4. Remove the blockage 5. Defective motor 5. Call 1-800-346-7611 Pump will not 1. Air leak in suction line 1. Repair or replace suction line prime or retain 2. Impeller is blocked 2.