Replacement Filter Cartridge Model No.: WDS-DA2900003G
Operating Specifications:
Operating Temperature: 33°F-100°F (0.6°C-38°C)
Working Pressure: 20 psi-100 psi (140 kPa-689 kPa)
Rated Capacity: 300 gallons (1,137 litres)
Flow Rate: 0.5 gpm (1.9 lpm)
Substance Reduction:
The system has been tested and certified by the NSF International according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for thewater leaving the system, as
specified by NSF/ANSI Standards 42 and 53. While testing was performed under standard laboratory conditions,
actual performance may vary.
PERFORMANCE DATA SHEET:
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system. Systems certified for cyst reduction may be used with disinfected water that may contain
filterable cysts.
Designed by HongKong Ecoaqua Co., Limited
Made in PRC
Substance
Chlorine Taste
and Odor
2.1 mg/L
Inf. Average
0.063 mg/L N/A97.0% ≥50%2.0mg/L ± 10%
NSF Specified
Challenge
Concentration
Max Permissible
Product Water
Concentration
NSF Reduction
Requirements
Average
Product Water
Concentration
Ave. %
Reduction (%)
Benzene
Lead (pH 8.5)
Lead (pH 6.5)
Cyst
15 ug/L
73 ug/L
140 ug/L
140 ug/L
120,000
oocysts/L
Carbofuran
0.5 ug/L
2 ug/L
0.5 ug/L
0.5 ug/L
0.5 ug/L
40 ug/L
10 ug/L
10 ug/L
96.6%
98.4%
99.6%
99.6%
N/A
N/A
N/A
N/A
N/A
J-00268283
J-00268284
J-00268279
J-00268280
15 ug/L ± 10%
73 ug/L ± 10%
140 ug/L ± 10%
140 ug/L ± 10%
1 oocysts/L N/A
>99.99%
J-00263594
minimum
50000 oocysts/L
NSF Test
Report
≥99.95%
REPLACEMENT
ELEMENT
Tested and Certified by NSF International against NSF/ANSI
Standards 42 and 53 for the reduction of the claims
specified on the Performance Data Sheet, and to NSF/ANSI
372 (≤ 0.25% lead).