Installation manual

23
PREMIER INSTALLATION MANUAL
1
2
3
P10
4
5
PB2
Auxiliary Electric Heat Power
208-230/60/3
Withoptional ' EA' Series
Auxiliary ElectricHeat
Typical schematic shown
2
3
HE1 TS1
HE2 TS2
HE3 TS3
P7
L1
L2
Yel
Blk
Gray
Yel
Blk
Gray
Gray
Blk
Yel
Gray
Blk
Yel
Yel
Blk
Gray
Blk
Gray
Grn
F2
P9
ER1
ER2
ER3
ER4
L3
NO
NO
NO
NO
Brn
Or
Brn
Or
5
4
Pink
Orange
White
Tan
Blue
Red
6
EA Series PCB
17P514A01
Notes:
2 - Connection of remote unit that does not have a loop pump for slave
operation
3 - 24V Accessory relay (see SW2 - 3 for description of operation)
4 - The blk/wh and gray/wh wires are removed when Aux Heat is installed
(ECM2 only).
Logic Board Physical Layout
1
123
P10
456
P2
1
4
3
2
1
P8
1
2
3
4
Thermistor
Light emitting diode - Green
Relay coil
Capacitor w/ bleed resistor
Switch - Condensate overflow
Switch - High pressure
Switch - Lowpressure
Switch -Hot Water On/Off
Polarized connector
Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quickconnect terminal
Wire nut
Field wire lug
Ground
Fuse
CC -
CO -
CR1 -
CR2-
CR3 -
CR4 -
F1 and F2 -
FP -
HE -
HP -
LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -
Compressor Contactor
Condensate overflow sensor
DHW pump relay
Loop pump relay
Fuses
Freeze protection sensor
Heater element
High pressure switch
Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 12 position
DIP package 8 position
DIP package 5 position
Hot water pump enable switch
Thermal limit switch
Legend
Relay Contacts-
N.O., N.C.
G
T
1
3
2
P
L1
PSC Fan Speed Relay
PSC Fan Power Relay
ER1 to ER4- Aux heat stagerelays
HWL -
Hot water limit sensor
123
1
P4
On
Off
SW1
240V - L2
240V - L1
Fused L2
Fused L2
Fused L2
F1
F1
R
R
Microprocessor
SeriesLogic Board
17P513A02
CR2- Loop
Pump
N.O.
240V - L2
240V - L1
C
C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
P6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
P5
Fused L2
Fused L1
CR1- DHW
Pump
N.O.
CC
CC-GND
CCLO
CCHI
123
P3
2
3
4
5
6
7
8
9
10
11
12
1
OnOff
SW2
2
3
4
5
6
7
8
1
OnOff
SW3
2
3
4
5
P1
1234567 8
2
345
P2
671
R C Y1 Y2 GOWL
Shut
Down
ACC
NO
ACC
NC
ACC
COM
CC
SL1
IN
SL1
Out
SL2
IN
SL2
Out
G
5 - Air Flow Configuration Example: SW1 configured for dip 3 as low, dip 5
as medium, anddip 7 as highspeed ECM2 fan.
6 - SW3-4 should be in the ON position when using Electric Heat control
17P514A01, and it should be in the OFF position when using Electric
Heat control 17P501A01.
7 - When using thermostat TA32E12, SW2 -8 should be in the ON position.
When using 24VACthermostats, SW2-8 should be in the OFF position.
3
15
16
10
8
P12
5
4
3
2
1
O
r
Br
n
8 - When optional electronic air-filter isinstalled, power for the electronic air-
filter is provided by P2-2 and 24 VAC.
Factory Blower voltage wiring
N.O.
CR4-
Com
N.O.
CR3-
Com
N.C.
1 - Place switch to 208V position to operate unit at 208V.
CS - Current Switch
9- SW3-2shouldbeOFFtooperatewithzonecontrolsystemandONto
operate with un-zoned system.