Installation manual

28
PREMIER INSTALLATION MANUAL
Fan Performance Data
ECM2 Motor
MODEL
MAX
ESP
AIRFLOW DIP SWITCH SETTINGS
123456789101112
P019 0.5
300 400 500 600 700 800
LMH
P022 0.5
400 500 600 700 800 900
LMH
P028 0.5
400 500 600 700 800 900 1000 1100
LMH
P034 0.5
600 700 800 900 1000 1100 1150 1225 1300
LMH
P040 0.5
650 750 850 950 1050 1150 1250 1325 1375 1475
LM H
P046 0.5
650 750 850 950 1050 1150 1250 1325 1375 1475 1550 1600
LM H
P040
w/1hp*
0.75
800 1000 1100 1300 1500
LM H
P046
w/1hp*
0.75
800 1000 1100 1300 1500 1600 1800
LM H
P056 0.75
750 900 1000 1200 1400 1600 1700 1850 2000 2200 2300 2400
LM H
P066 0.75
750 900 1000 1200 1400 1600 1700 1850 2000 2200 2300 2400
LM H
A 12-position DIP switch package on the control allows the air ow levels to be set for low,
medium, and high speed when using the ECM2 blower motor. Only three of the DIP switches
can be in the "on" position.
The rst "on" switch (the lowest position number) determines the low speed fan setting.
The second "on" switch determines the medium speed fan setting.
The third "on" switch determines the high speed fan setting.
The example to the right shows SW1 on the control board con gured for the following P028
air ow settings.
Low Speed Fan: 500 CFM
Medium Speed Fan: 700 CFM
High Speed Fan: 900 CFM
1
2
3
4
5
6
7
8
9
10
11
12
SW1
OnOff
Notes: Factory settings are at recommended L-M-H DIP switch locations.
Factory L setting is minimum allowed for cooling.
M-H settings must be located within shaded CFM range.
CFM is controlled within 5% up to the maximum ESP.
Max ESP includes allowance for wet coil and standard lter.
* With optional 1 HP fan motor.