Operating instructions
The Cube Technical Manual - Version 1, May 2014
30 31
Dip Switch Setup
FILTER TIMER SETTING
A combination of dip switches 2 
& 3 is used to enter this setup.
• 3month 
• 6month 
• 12month 
• No filter timer 
UV SETTING
• CS = CDS Sensor 
 (Used in Europe)
• US = UV Sensor
COLD WATER 
TEMPERATURE 
SETTING 
Cold water temp range: 
• 5⁰c
• 10⁰c
• 15⁰c
When reading this document please note the white coloring on the diagrams 
indicate the required position of the switch to determine the setting.
UV 1
CS
US 
FILTER 2  3
3M
6M
12M
NO 
CTEMP 1  2
5˚c 
10˚c 
10˚c
15˚c
HOT WATER 
TEMPERATURE 
SETTING 
Hot water temp range: 
• 80°C
• 87°C
• 95°C
HTEMP 3  4
80 ˚c
87 ˚c
87 ˚c
95 ˚c
SLEEP MODE 
Hot water temp range: 
• ON
• OFF
HSLP 5 
ON
OFF 
DIP SWITCH 1 SETUP
DP1 
DIP SWITCH 2 SETUP
DP2 