Installation Sheet

J
G
H
K
EXTEND 1/4”
5.
6.
4.
Slide compression nut (G)
over end of blue supply
tube (H). Slide ferrule (J)
onto end of blue supply
tube, long tapered end
rst. Push tube insert
(K) into top of blue
supply tube.
Slide ferrule until 1/4”
of tubing is showing
out the end.
Insert extended
portion of tubing and
tighten compression
nut to end of faucet
shank with wrench.
M
N
RETAINING CLIPS
CARBON FINES
AND MILKY
APPEARANCE
IN WATER
INVERT UNIT
SYSTEM ACTIVATION AND INSPECTION
Open the dispensing faucet at the sink. Next, open the
feed water valve to the system (M), then angle stop
(N). Observe all tubing and connections for several
minutes to detect any leaks. Allow the faucet to run for
at least 3 minutes, then close the faucet. During the
3-minute ush, a small amount of carbon nes may be
seen in the initial ushing of the system. This is normal.
The water also may appear to be milky. This is due to
air being trapped in system. If practical, invert the unit
until air ceases to purge from the faucet. Check ttings
again for leaks after closing the faucet. The system is
now ready for use.
Check all tubing connections to ensure
they are rmly seated. CHECK TO SEE
THAT THE CARTRIDGE RETAINER
CLIP IS PROPERLY INSTALLED WITH
THE SLIDE LOCKS FULLY ENGAGED
IN FRAME SLOTS. The retainer clip
must be in place during long term ,
unattended operation of the system.
Failure to keep the retaining clip
properly engaged could result in
accidental leaks and ooding.