Manual

WATLOW DIN-A-MITE Style C User's Manual
5
Output Rating Curves
05101520253035404550556065707580
25
30
35
40
45
50
55
60
65
70
75
80
90
85
Current (Amps) into a Resistive Load
Maximum Internal Enclosure Ambient Temperature (°C)
DIN-A-MITE Style C Ratings at 100% On
Natural Convection
3
-
pha
s
e
, 3
-
le
g
3-
phase, 2-
leg
S
ingle-phase
0510152025303540455055606570
25
30
35
40
45
50
55
60
65
70
Current (Amps) into a Resistive Load
Maximum Internal Enclosure Ambient Temperature (°C)
DIN-A-MITE Style C Ratings at 100% On
75 80 85 90
Fan-Cooled
75
80
3-p
h
a
se,
3
-l
eg
3-
phase,
2-
l
eg
Si
ng
l
e-
phase
Extended Heater And SCR Life
With Variable Time Base
Models: DC _ _ - [02, 24, 60] F0 - _ _ _ _
20% Power, 3 AC line cycles on, 12 cycles off
50% Power, 3 AC line cycles on, 3 cycles off
Phase Angle
Single-Cycle Variable Time Base
With single-cycle variable time base (VTBS)
control, at 50% power, power is on one cycle, and
off one cycle. At 25%, it is on for one cycle and
off for three. Under 50%, the unit is not on for
more than one consecutive cycle. Over 50%, the
unit is not off for more than one consecutive
cycle. This model will work with a linear voltage
input, a 4 to 20mA input or a potentiometer
input.
Phase angle control (control Type P) is infinitely
variable inside the sine wave. This provides a
variable voltage and/or current output. This
option includes soft start and line voltage
compensation. This model will work with a linear
voltage input, a linear current source input or a
potentiometer input. This is single-phase only.
Alarms not available on phase angle models.
Models: DC _ _ - _ _ S _ - _ _ _ _
25% Power, 1 AC line cycle on, 3 cycles off
Models: DC1 _ - _ _ [L, P] _ - 0 _ _ _
With variable time base control, the power
controller automatically adjusts the time base
and output power with respect to process input.
Accelerated life testing verified that the variable
time base control significantly reduces
expansion and contraction of the heater element.
This extends heater and SCR life while
improving the process temperature control. You
save money on heaters, down time and
maintenance.
50% Power, 1 AC line cycle on, 1 cycle off
Ó
6
0510152025303540455055606570
Current (Amps) into a Resistive Load
25
30
35
40
45
50
55
60
65
70
75
80
Ambient Air Around Heatsink Fins ( C)
DIN-A-MITE Style C Ratings at 100% On
Through-Wall Heatsink
75 80
Recommended maximum 
enclosure temperature is 80 C (176 F)
3
-
p
h
a
s
e
,
2
-
l
e
g
3
-
p
h
a
s
e
,
3
-
l
e
g
S
i
n
g
l
e
-
p
h
a
s
e
Combination Fuses for Applications Through 600VÅ (ac):
Semiconductor Watlow Fuse Bussman Watlow Holder Bussmann Holder
Fuse Rating P/N P/N P/N P/N
3
0A 0808-0325-0030 DFJ30 0808-0326-1530 CH30J1i
40A 0808-0325-0040 DFJ40 0808-0325-3560 CH60J1i
50A 0808-0325-0050 DFJ50 0808-0325-3560 CH60J1i
6
3A 0808-0325-0060 DFJ60 0808-0325-3560 CH60J1i
80A 0808-0325-0080 DFJ80 0808-0325-7010 J60100-1CR
100A 0808-0325-0100 DFJ100 0808-0325-7010 J60100-1CR