Line
Voltage Input Temp Range
Control
Mode
Action
Output Set Point Mounting Retrofit control
See Notes
Below
146D-2P1D-1200 230 VAC 100 ohm DIN -100 to 1112 °F High Limit
Manual Reset
3A Relay Remote DIN Rail LV E5PU -100 1112 A
2, 6, 8
146D-2P1D-2100 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Manual Reset
3A Relay Integral DIN Rail LV E6RY -073 0600 A
6, 8
146D-2P1D-2100 230 VAC 100 ohm DIN -100 to 1112 °F Low Limit
Manual Reset
3A Relay Integral DIN Rail LV E6PY -100 1112 A
6, 8
146D-2P1D-2200 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Manual Reset
3A Relay Remote DIN Rail LV E5RY -073 0600 A
2, 6, 8
146D-2P1D-2200 230 VAC 100 ohm DIN -100 to 1112 °F Low Limit
Manual Reset
3A Relay Remote DIN Rail LV E5PY -100 1112 A
2, 6, 8
146D-2P1D-3100 230 VAC 100 ohm DIN -73 to 600°C High Limit
Auto Reset
3A Relay Integral DIN Rail LV E6RW -073 0600 A
6, 8
146D-2P1D-3100 230 VAC 100 ohm DIN -100 to 1112 °F High Limit
Auto Reset
3A Relay Integral DIN Rail LV E6PW -100 1112 A
6, 8
146D-2P1D-3200 230 VAC 100 ohm DIN -73 to 600°C High Limit
Auto Reset
3A Relay Remote DIN Rail LV E5RW -073 0600 A
2, 6, 8
146D-2P1D-3200 230 VAC 100 ohm DIN -100 to 1112 °F High Limit
Auto Reset
3A Relay Remote DIN Rail LV E5PW -100 1112 A
2, 6, 8
146D-2P1D-4100 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Auto Reset
3A Relay Integral DIN Rail LV E6RZ -073 0600 A
6, 8
146D-2P1D-4100 230 VAC 100 ohm DIN -100 to 1112 °F Low Limit
Auto Reset
3A Relay Integral DIN Rail LV E6PZ -100 1112 A
6, 8
146D-2P1D-4200 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Auto Reset
3A Relay Remote DIN Rail LV E5RZ -073 0600 A
2, 6, 8
146D-2P1D-4200 230 VAC 100 ohm DIN -100 to 1112 °F Low Limit
Auto Reset
3A Relay Remote DIN Rail LV E5PZ -100 1112 A
2, 6, 8
146D-2P1F-1100 230 VAC 100 ohm DIN -100 to 1112 °F High Limit
Manual Reset
3A Relay Integral DIN Rail LV E6PU -100 1112 A
6
146D-2P1F-1200 230 VAC 100 ohm DIN -100 to 1112 °F High Limit
Manual Reset
3A Relay Remote DIN Rail LV E5PU -100 1112 A
2, 6
146D-2P1F-2100 230 VAC 100 ohm DIN -100 to 1112 °F Low Limit
Manual Reset
3A Relay Integral DIN Rail LV E6PY -100 1112 A
6
146D-2P1F-2200 230 VAC 100 ohm DIN -100 to 1112 °F Low Limit
Manual Reset
3A Relay Remote DIN Rail LV E5PY -100 1112 A
2, 6
146D-2P1F-3100 230 VAC 100 ohm DIN -100 to 1112 °F High Limit
Auto Reset
3A Relay Integral DIN Rail LV E6PW -100 1112 A
6
146D-2P1F-3200 230 VAC 100 ohm DIN -100 to 1112 °F High Limit
Auto Reset
3A Relay Remote DIN Rail LV E5PW -100 1112 A
2, 6
146D-2P1F-4100 230 VAC 100 ohm DIN -100 to 1112 °F Low Limit
Auto Reset
3A Relay Integral DIN Rail LV E6PZ -100 1112 A
6
146D-2P1F-4200 230 VAC 100 ohm DIN -100 to 1112 °F Low Limit
Auto Reset
3A Relay Remote DIN Rail LV E5PZ -100 1112 A
2, 6
146D-2T1C-1100 230 VAC T t/c -200 to 350°C High Limit
Manual Reset
3A Relay Integral DIN Rail LV E6NU -200 0350 A
6
146D-2T1C-1200 230 VAC T t/c -200 to 350°C High Limit
Manual Reset
3A Relay Remote DIN Rail LV E5NU -200 0350 A
2, 6
146D-2T1C-2100 230 VAC T t/c -200 to 350°C Low Limit
Manual Reset
3A Relay Integral DIN Rail LV E6NY -200 0350 A
6
146D-2T1C-2200 230 VAC T t/c -200 to 350°C Low Limit
Manual Reset
3A Relay Remote DIN Rail LV E5NY -200 0350 A
2, 6
146D-2T1C-3100 230 VAC T t/c -200 to 350°C High Limit
Auto Reset
3A Relay Integral DIN Rail LV E6NW -200 0350 A
6
146D-2T1C-3200 230 VAC T t/c -200 to 350°C High Limit
Auto Reset
3A Relay Remote DIN Rail LV E5NW -200 0350 A
2, 6
146D-2T1C-4100 230 VAC T t/c -200 to 350°C Low Limit
Auto Reset
3A Relay Integral DIN Rail LV E6NZ -200 0350 A
6
146D-2T1C-4200 230 VAC T t/c -200 to 350°C Low Limit
Auto Reset
3A Relay Remote DIN Rail LV E5NZ -200 0350 A
2, 6
146D-2T1D-1100 230 VAC T t/c -328 to 662°F High Limit
Manual Reset
3A Relay Integral DIN Rail LV E6MU -328 0662 A
6, 8
146D-2T1D-1100 230 VAC T t/c -200 to 350°C High Limit
Manual Reset
3A Relay Integral DIN Rail LV E6NU -200 0350 A
6, 8
146D-2T1D-1200 230 VAC T t/c -328 to 662°F High Limit
Manual Reset
3A Relay Remote DIN Rail LV E5MU -328 0662 A
2, 6, 8
146D-2T1D-1200 230 VAC T t/c -200 to 350°C High Limit
Manual Reset
3A Relay Remote DIN Rail LV E5NU -200 0350 A
2, 6, 8
146D-2T1D-2100 230 VAC T t/c -328 to 662°F Low Limit
Manual Reset
3A Relay Integral DIN Rail LV E6MY -328 0662 A
6, 8
146D-2T1D-2100 230 VAC T t/c -200 to 350°C Low Limit
Manual Reset
3A Relay Integral DIN Rail LV E6NY -200 0350 A
6, 8
146D-2T1D-2200 230 VAC T t/c -328 to 662°F Low Limit
Manual Reset
3A Relay Remote DIN Rail LV E5MY -328 0662 A
2, 6, 8
146D-2T1D-2200 230 VAC T t/c -200 to 350°C Low Limit
Manual Reset
3A Relay Remote DIN Rail LV E5NY -200 0350 A
2, 6, 8
146D-2T1D-3100 230 VAC T t/c -328 to 662°F High Limit
Auto Reset
3A Relay Integral DIN Rail LV E6MW -328 0662 A
6, 8
146D-2T1D-3100 230 VAC T t/c -200 to 350°C High Limit
Auto Reset
3A Relay Integral DIN Rail LV E6NW -200 0350 A
6, 8
146D-2T1D-3200 230 VAC T t/c -328 to 662°F High Limit
Auto Reset
3A Relay Remote DIN Rail LV E5MW -328 0662 A
2, 6, 8
146D-2T1D-3200 230 VAC T t/c -200 to 350°C High Limit
Auto Reset
3A Relay Remote DIN Rail LV E5NW -200 0350 A
2, 6, 8
Watlow Controls 3/30/2005 Page 20