User guide
Series 146
Series 146
Line
Voltage Input Temp Range
Control
Mode
Action
Output Set Point Mounting Retrofit control
See Notes
Below
146E-1619-4S00 120 VAC E t/c 0 to 799°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5TZ 0000 0799 A 2, 6, 8
146E-1620-1000 120 VAC J t/c 300 to 800°F High Limit
Manual Reset
8A Relay Integral DIN Rail LV C6HU 0300 0800 A 6, 8
146E-1620-1000 120 VAC J t/c 149 to 427°C High Limit
Manual Reset
8A Relay Integral DIN Rail LV C6JU 0149 0427 A 6, 8
146E-1620-1N00 120 VAC J t/c 300 to 800°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HU 0300 0800 A 2, 6, 8
146E-1620-1N00 120 VAC J t/c 149 to 427°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JU 0149 0427 A 2, 6, 8
146E-1620-1P00 120 VAC J t/c 300 to 800°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HU 0300 0800 A 2, 6, 8
146E-1620-1P00 120 VAC J t/c 149 to 427°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JU 0149 0427 A 2, 6, 8
146E-1620-1S00 120 VAC J t/c 300 to 800°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HU 0300 0800 A 2, 6, 8
146E-1620-1S00 120 VAC J t/c 149 to 427°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JU 0149 0427 A 2, 6, 8
146E-1620-2000 120 VAC J t/c 300 to 800°F Low Limit
Manual Reset
8A Relay Integral DIN Rail LV C6HY 0300 0800 A 6, 8
146E-1620-2000 120 VAC J t/c 149 to 427°C Low Limit
Manual Reset
8A Relay Integral DIN Rail LV C6JY 0149 0427 A 6, 8
146E-1620-2N00 120 VAC J t/c 300 to 800°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HY 0300 0800 A 2, 6, 8
146E-1620-2N00 120 VAC J t/c 149 to 427°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JY 0149 0427 A 2, 6, 8
146E-1620-2P00 120 VAC J t/c 300 to 800°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HY 0300 0800 A 2, 6, 8
146E-1620-2P00 120 VAC J t/c 149 to 427°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JY 0149 0427 A 2, 6, 8
146E-1620-2S00 120 VAC J t/c 300 to 800°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HY 0300 0800 A 2, 6, 8
146E-1620-2S00 120 VAC J t/c 149 to 427°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JY 0149 0427 A 2, 6, 8
146E-1620-3000 120 VAC J t/c 300 to 800°F High Limit
Auto Reset
8A Relay Integral DIN Rail LV C6HW 0300 0800 A 6, 8
146E-1620-3000 120 VAC J t/c 149 to 427°C High Limit
Auto Reset
8A Relay Integral DIN Rail LV C6JW 0149 0427 A 6, 8
146E-1620-3N00 120 VAC J t/c 300 to 800°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5HW 0300 0800 A 2, 6, 8
146E-1620-3N00 120 VAC J t/c 149 to 427°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5JW 0149 0427 A 2, 6, 8
146E-1620-3P00 120 VAC J t/c 300 to 800°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5HW 0300 0800 A 2, 6, 8
146E-1620-3P00 120 VAC J t/c 149 to 427°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5JW 0149 0427 A 2, 6, 8
146E-1620-3S00 120 VAC J t/c 300 to 800°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5HW 0300 0800 A 2, 6, 8
146E-1620-3S00 120 VAC J t/c 149 to 427°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV C5JW 0149 0427 A 2, 6, 8
146E-1620-4000 120 VAC J t/c 300 to 800°F Low Limit
Auto Reset
8A Relay Integral DIN Rail LV C6HZ 0300 0800 A 6, 8
146E-1620-4000 120 VAC J t/c 149 to 427°C Low Limit
Auto Reset
8A Relay Integral DIN Rail LV C6JZ 0149 0427 A 6, 8
146E-1620-4N00 120 VAC J t/c 300 to 800°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5HZ 0300 0800 A 2, 6, 8
146E-1620-4N00 120 VAC J t/c 149 to 427°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5JZ 0149 0427 A 2, 6, 8
146E-1620-4P00 120 VAC J t/c 300 to 800°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5HZ 0300 0800 A 2, 6, 8
146E-1620-4P00 120 VAC J t/c 149 to 427°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5JZ 0149 0427 A 2, 6, 8
146E-1620-4S00 120 VAC J t/c 300 to 800°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5HZ 0300 0800 A 2, 6, 8
146E-1620-4S00 120 VAC J t/c 149 to 427°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV C5JZ 0149 0427 A 2, 6, 8
146E-1623-1000 120 VAC J t/c 110 to 130°F High Limit
Manual Reset
8A Relay Integral DIN Rail LV C6HU 0110 0130 A 6, 8
146E-1623-1000 120 VAC J t/c 43 to 54°C High Limit
Manual Reset
8A Relay Integral DIN Rail LV C6JU 0043 0054 A 6, 8
146E-1623-1N00 120 VAC J t/c 110 to 130°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HU 0110 0130 A 2, 6, 8
146E-1623-1N00 120 VAC J t/c 43 to 54°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JU 0043 0054 A 2, 6, 8
146E-1623-1P00 120 VAC J t/c 110 to 130°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HU 0110 0130 A 2, 6, 8
146E-1623-1P00 120 VAC J t/c 43 to 54°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JU 0043 0054 A 2, 6, 8
146E-1623-1S00 120 VAC J t/c 110 to 130°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5HU 0110 0130 A 2, 6, 8
146E-1623-1S00 120 VAC J t/c 43 to 54°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV C5JU 0043 0054 A 2, 6, 8
Watlow Controls 3/30/2005 Page 40