User guide
Series 146
Series 146
Line
Voltage Input Temp Range
Control
Mode
Action
Output Set Point Mounting Retrofit control
See Notes
Below
146E-1T1D-2200 120 VAC T t/c -200 to 350°C Low Limit
Manual Reset
10A Relay Remote DIN Rail LV C5NY -200 0350 A 2, 3, 6, 8
146E-1T1D-3100 120 VAC T t/c -328 to 662°F High Limit
Auto Reset
10A Relay Integral DIN Rail LV C6MW -328 0662 A
3, 6, 8
146E-1T1D-3100 120 VAC T t/c -200 to 350°C High Limit
Auto Reset
10A Relay Integral DIN Rail LV C6NW -200 0350 A
3, 6, 8
146E-1T1D-3200 120 VAC T t/c -328 to 662°F High Limit
Auto Reset
10A Relay Remote DIN Rail LV C5MW -328 0662 A 2, 3, 6, 8
146E-1T1D-3200 120 VAC T t/c -200 to 350°C High Limit
Auto Reset
10A Relay Remote DIN Rail LV C5NW -200 0350 A 2, 3, 6, 8
146E-1T1D-4100 120 VAC T t/c -328 to 662°F Low Limit
Auto Reset
10A Relay Integral DIN Rail LV C6MZ -328 0662 A
3, 6, 8
146E-1T1D-4100 120 VAC T t/c -200 to 350°C Low Limit
Auto Reset
10A Relay Integral DIN Rail LV C6NZ -200 0350 A
3, 6, 8
146E-1T1D-4200 120 VAC T t/c -328 to 662°F Low Limit
Auto Reset
10A Relay Remote DIN Rail LV C5MZ -328 0662 A 2, 3, 6, 8
146E-1T1D-4200 120 VAC T t/c -200 to 350°C Low Limit
Auto Reset
10A Relay Remote DIN Rail LV C5NZ -200 0350 A 2, 3, 6, 8
146E-1T1F-1100 120 VAC T t/c -328 to 662°F High Limit
Manual Reset
10A Relay Integral DIN Rail LV C6MU -328 0662 A
3, 6
146E-1T1F-1200 120 VAC T t/c -328 to 662°F High Limit
Manual Reset
10A Relay Remote DIN Rail LV C5MU -328 0662 A 2, 3, 6
146E-1T1F-2100 120 VAC T t/c -328 to 662°F Low Limit
Manual Reset
10A Relay Integral DIN Rail LV C6MY -328 0662 A
3, 6
146E-1T1F-2200 120 VAC T t/c -328 to 662°F Low Limit
Manual Reset
10A Relay Remote DIN Rail LV C5MY -328 0662 A 2, 3, 6
146E-1T1F-3100 120 VAC T t/c -328 to 662°F High Limit
Auto Reset
10A Relay Integral DIN Rail LV C6MW -328 0662 A
3, 6
146E-1T1F-3200 120 VAC T t/c -328 to 662°F High Limit
Auto Reset
10A Relay Remote DIN Rail LV C5MW -328 0662 A 2, 3, 6
146E-1T1F-4100 120 VAC T t/c -328 to 662°F Low Limit
Auto Reset
10A Relay Integral DIN Rail LV C6MZ -328 0662 A
3, 6
146E-1T1F-4200 120 VAC T t/c -328 to 662°F Low Limit
Auto Reset
10A Relay Remote DIN Rail LV C5MZ -328 0662 A 2, 3, 6
146E-2101-1000 230 VAC 100 ohm DIN -73 to 600°C High Limit
Manual Reset
8A Relay Integral DIN Rail LV E6RU -073 0600 A 6, 8
146E-2101-1000 230 VAC 100 ohm DIN -100 to 1112°F High Limit
Manual Reset
8A Relay Integral DIN Rail LV E6PU -100 1112 A 6, 8
146E-2101-1N00 230 VAC 100 ohm DIN -73 to 600°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RU -073 0600 A 2, 6, 8
146E-2101-1N00 230 VAC 100 ohm DIN -100 to 1112°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PU -100 1112 A 2, 6, 8
146E-2101-1P00 230 VAC 100 ohm DIN -73 to 600°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RU -073 0600 A 2, 6, 8
146E-2101-1P00 230 VAC 100 ohm DIN -100 to 1112°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PU -100 1112 A 2, 6, 8
146E-2101-1S00 230 VAC 100 ohm DIN -73 to 600°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RU -073 0600 A 2, 6, 8
146E-2101-1S00 230 VAC 100 ohm DIN -100 to 1112°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PU -100 1112 A 2, 6, 8
146E-2101-2000 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Manual Reset
8A Relay Integral DIN Rail LV E6RY -073 0600 A 6, 8
146E-2101-2000 230 VAC 100 ohm DIN -100 to 1112°F Low Limit
Manual Reset
8A Relay Integral DIN Rail LV E6PY -100 1112 A 6, 8
146E-2101-2N00 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RY -073 0600 A 2, 6, 8
146E-2101-2N00 230 VAC 100 ohm DIN -100 to 1112°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PY -100 1112 A 2, 6, 8
146E-2101-2P00 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RY -073 0600 A 2, 6, 8
146E-2101-2P00 230 VAC 100 ohm DIN -100 to 1112°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PY -100 1112 A 2, 6, 8
146E-2101-2S00 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RY -073 0600 A 2, 6, 8
146E-2101-2S00 230 VAC 100 ohm DIN -100 to 1112°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PY -100 1112 A 2, 6, 8
146E-2101-3000 230 VAC 100 ohm DIN -73 to 600°C High Limit
Auto Reset
8A Relay Integral DIN Rail LV E6RW -073 0600 A 6, 8
146E-2101-3000 230 VAC 100 ohm DIN -100 to 1112°F High Limit
Auto Reset
8A Relay Integral DIN Rail LV E6PW -100 1112 A 6, 8
146E-2101-3N00 230 VAC 100 ohm DIN -73 to 600°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RW -073 0600 A 2, 6, 8
146E-2101-3N00 230 VAC 100 ohm DIN -100 to 1112°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PW -100 1112 A 2, 6, 8
146E-2101-3P00 230 VAC 100 ohm DIN -73 to 600°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RW -073 0600 A 2, 6, 8
146E-2101-3P00 230 VAC 100 ohm DIN -100 to 1112°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PW -100 1112 A 2, 6, 8
146E-2101-3S00 230 VAC 100 ohm DIN -73 to 600°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RW -073 0600 A 2, 6, 8
146E-2101-3S00 230 VAC 100 ohm DIN -100 to 1112°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PW -100 1112 A 2, 6, 8
Watlow Controls 3/30/2005 Page 56