User guide

Series 146
Series 146
Line
Voltage Input Temp Range
Control
Mode
Action
Output Set Point Mounting Retrofit control
See Notes
Below
146E-3623-2N00 24 VAC J t/c 110 to 130°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5HY 0110 0130 A 2, 6, 8
146E-3623-2N00 24 VAC J t/c 43 to 54°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5JY 0043 0054 A 2, 6, 8
146E-3623-2P00 24 VAC J t/c 110 to 130°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5HY 0110 0130 A 2, 6, 8
146E-3623-2P00 24 VAC J t/c 43 to 54°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5JY 0043 0054 A 2, 6, 8
146E-3623-2S00 24 VAC J t/c 110 to 130°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5HY 0110 0130 A 2, 6, 8
146E-3623-2S00 24 VAC J t/c 43 to 54°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5JY 0043 0054 A 2, 6, 8
146E-3623-3000 24 VAC J t/c 110 to 130°F High Limit
Auto Reset
8A Relay Integral DIN Rail LV G6HW 0110 0130 A 6, 8
146E-3623-3000 24 VAC J t/c 43 to 54°C High Limit
Auto Reset
8A Relay Integral DIN Rail LV G6JW 0043 0054 A 6, 8
146E-3623-3N00 24 VAC J t/c 110 to 130°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV G5HW 0110 0130 A 2, 6, 8
146E-3623-3N00 24 VAC J t/c 43 to 54°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV G5JW 0043 0054 A 2, 6, 8
146E-3623-3P00 24 VAC J t/c 110 to 130°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV G5HW 0110 0130 A 2, 6, 8
146E-3623-3P00 24 VAC J t/c 43 to 54°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV G5JW 0043 0054 A 2, 6, 8
146E-3623-3S00 24 VAC J t/c 110 to 130°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV G5HW 0110 0130 A 2, 6, 8
146E-3623-3S00 24 VAC J t/c 43 to 54°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV G5JW 0043 0054 A 2, 6, 8
146E-3623-4000 24 VAC J t/c 110 to 130°F Low Limit
Auto Reset
8A Relay Integral DIN Rail LV G6HZ 0110 0130 A 6, 8
146E-3623-4000 24 VAC J t/c 43 to 54°C Low Limit
Auto Reset
8A Relay Integral DIN Rail LV G6JZ 0043 0054 A 6, 8
146E-3623-4N00 24 VAC J t/c 110 to 130°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV G5HZ 0110 0130 A 2, 6, 8
146E-3623-4N00 24 VAC J t/c 43 to 54°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV G5JZ 0043 0054 A 2, 6, 8
146E-3623-4P00 24 VAC J t/c 110 to 130°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV G5HZ 0110 0130 A 2, 6, 8
146E-3623-4P00 24 VAC J t/c 43 to 54°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV G5JZ 0043 0054 A 2, 6, 8
146E-3623-4S00 24 VAC J t/c 110 to 130°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV G5HZ 0110 0130 A 2, 6, 8
146E-3623-4S00 24 VAC J t/c 43 to 54°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV G5JZ 0043 0054 A 2, 6, 8
146E-3625-1000 24 VAC J t/c 250 to 430°F High Limit
Manual Reset
8A Relay Integral DIN Rail LV G6HU 0250 0430 A 6, 8
146E-3625-1000 24 VAC J t/c 121 to 221°C High Limit
Manual Reset
8A Relay Integral DIN Rail LV G6JU 0121 0221 A 6, 8
146E-3625-1N00 24 VAC J t/c 250 to 430°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV G5HU 0250 0430 A 2, 6, 8
146E-3625-1N00 24 VAC J t/c 121 to 221°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV G5JU 0121 0221 A 2, 6, 8
146E-3625-1P00 24 VAC J t/c 250 to 430°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV G5HU 0250 0430 A 2, 6, 8
146E-3625-1P00 24 VAC J t/c 121 to 221°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV G5JU 0121 0221 A 2, 6, 8
146E-3625-1S00 24 VAC J t/c 250 to 430°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV G5HU 0250 0430 A 2, 6, 8
146E-3625-1S00 24 VAC J t/c 121 to 221°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV G5JU 0121 0221 A 2, 6, 8
146E-3625-2000 24 VAC J t/c 250 to 430°F Low Limit
Manual Reset
8A Relay Integral DIN Rail LV G6HY 0250 0430 A 6, 8
146E-3625-2000 24 VAC J t/c 121 to 221°C Low Limit
Manual Reset
8A Relay Integral DIN Rail LV G6JY 0121 0221 A 6, 8
146E-3625-2N00 24 VAC J t/c 250 to 430°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5HY 0250 0430 A 2, 6, 8
146E-3625-2N00 24 VAC J t/c 121 to 221°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5JY 0121 0221 A 2, 6, 8
146E-3625-2P00 24 VAC J t/c 250 to 430°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5HY 0250 0430 A 2, 6, 8
146E-3625-2P00 24 VAC J t/c 121 to 221°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5JY 0121 0221 A 2, 6, 8
146E-3625-2S00 24 VAC J t/c 250 to 430°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5HY 0250 0430 A 2, 6, 8
146E-3625-2S00 24 VAC J t/c 121 to 221°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV G5JY 0121 0221 A 2, 6, 8
146E-3625-3000 24 VAC J t/c 250 to 430°F High Limit
Auto Reset
8A Relay Integral DIN Rail LV G6HW 0250 0430 A 6, 8
146E-3625-3000 24 VAC J t/c 121 to 221°C High Limit
Auto Reset
8A Relay Integral DIN Rail LV G6JW 0121 0221 A 6, 8
146E-3625-3N00 24 VAC J t/c 250 to 430°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV G5HW 0250 0430 A 2, 6, 8
Watlow Controls 3/30/2005 Page 91