8.2 Warnings handling
All warnings are cleared automatically, when data within limits are received via FB, or with clear-bit:
MC100 command B1.4
In warning 08-13 by the phrase individual pumps, means “real” connected pumps and pump 0
means the pseudo pump, which holds common parameters in parallel and serial mode
8.2.1 Warnings
Warning no. Warning description Action
0 No pending warnings
1 Fill volume out of range
Attempt to set parameter that is
outside limits.
Set new parameter.
2 Tube number is not in table
3 Speed setting is out of range
4 Acceleration setting is out of range
5 Reverse setting is out of range
6 Density setting is out of range
7 Calibration is out of range
8 Common calibration in parallel
Calibration attempt for individual
pump, calibrate pump 0 only.
9 Individual calibration in serial
Calibration attempt for Pump 0,
calibrate pumps individually
10
Attempt to setting common parameters to
individual pump in serial mode
Use pump 0 or clear warning
11
Attempt to calibrate common pump in
Individual mode
Clear by calibrating physical
connected pumps