INSTALLATION, OPERATION AND MAINTENANCE MANUAL Warning Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure. Save manual for future reference Model: RO-PURE System Tested and certified by WQA against NSF/ANSI Standard 58 for the reduction of the claims specified on the performance data sheet. Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Thank you for your purchase of a state of the art Premier Reverse Osmosis (RO) water treatment system. Water quality concerns are becoming more of a focus for the public. You may have heard about contaminants in the drinking water such as Arsenic, Chromium, Cryptosporidium or Giardia. There may also be some local water issues such as high levels of Lead and Copper. This Premier water treatment system has been designed and tested to provide you with high quality drinking water for years to come.
** Before installation, please take a moment to fill out the warranty card on page 25. Table of Contents Operational Parameters.................................................................................................................... 4 Contents of Reverse Osmosis System............................................................................................. 4 Installation & Startup Tools Recommended For Installation.............................................................................
Operational Parameters Installation must comply with State and local plumbing regulations. Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system. System is intended to be installed using the cold water supply only. Operating Temperatures: Operating Pressure: pH Parameters: Iron: TDS (Total Dissolved Solids) Turbidity Hardness Maximum 100°F (37.8°C) Maximum 100 psi (7.0 kg/cm2) Maximum 11 Maximum 0.
Plumbing Diagram and Parts List 5 FAUCET 11 BLUE - 1/4” TUBE FAUCET RED - 1/4” TUBE BRINE 7 BLUE - 1/4” TUBE 6 TANK 1 3 12 13 TANK 2 AUTO SHUT-OFF VALVE 9 4 ADAPT -AVALVE 14 GREEN- 1/4” TUBE FEED COLD WATER ANGLE-STOP (SUPPLY) 15 16 17 Item # Part # Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 610051 134003 119007 560080 420063 134018 228173 164056 119028 142000 142001 400048 142002 105311 105351 105331 105341 FILTER HEAD & ASO VALVE SHUT
Drill a Hole for the Reverse Osmosis Faucet Marble Counter-top We recommend contacting a qualified contractor for drilling a hole in a marble counter-top. Counter Top / Porcelain & Stainless Steel Sink Note: Most sinks are pre drilled with 1 ¼” diameter hole that you can use for your RO faucet. (If you are already using it for a sprayer or soap dispenser, see step 1) Porcelain sinks are extremely hard and can crack or chip easily. Use extreme caution when drilling.
Premier Monitored (Top Mount) Faucet Installation A) Connect tubes to the RO faucet (Figure A) A This RO faucet is equipped with quick connect fittings for easy tube installation. To connect tubes, simply push them firmly into their corresponding fitting on the RO faucet until fully seated. (4) RED (3) BLACK In the parts bag, locate one 3/8” Stem x 1/4” Quick connect fitting adapter, one 1/4” red tube, one 1/4” blue tube and one 3/8” black tube. 1.
Helpful Installation Tips for the Watts Top Mount Faucet During shipping/handling the toggle bolt on your new faucet may push up out of position. Prior to the install, hold the faucet as shown in the picture and pull down on the wing nut. This will ensure that the O-rings are in their proper position and that your faucet will have a good seal. Disassembling your faucet is never recommended as this could void your warranty.
Adapt-a-Valve Installation Caution: Water supply line to the system must be from the cold water supply line only. Hot water will severely damage your system.
Drain Saddle Installation Drain Saddle fits standard 1 ¼” – 1 ½” drain pipes Caution: If you have a garbage disposal, do not install the drain saddle near it. Installation of the drain saddle must be either above the garbage disposal, or if a second sink drain is available, install it above the cross bar on the second drain. Installation of the drain saddle near a garbage disposal may cause the drain line to plug.
Rear View of RO-Pure System Mounting Holes BLUE TUBE - TANK GREEN TUBE RED TUBE - BRINE BLUE TUBE - FAUCET POST CARBON MEMBRANE PRE CARBON SEDIMENT Blue Tube Connection (From FAUCET To The RO Module) Step 13 Locate the 1/4” BLUE tube attached to the RO faucet. Insert the open end of the tube with the 90* bend into the open 1/4” quick connect fitting on the back side of the RO-Pure Head behind the Post Filter head making sure the tube is pushed in all the way to the tube stop.
Green Tube Connection Step 15 Locate green tube attached to the RO Module. Insert the open end of the green 1/4” tube into the open 1/4” quick connect fitting on the plastic water feed valve making sure the tube is pushed in all the way to the tube stop. Green Tube Adapt-a-Valve Reverse Osmosis Module Mounting Step 16 Determine best location for the RO module to be mounted to allow for future system maintenance. The parts bag has 2 self tapping screws.
Congratulations! You have completed the installation of your new Reverse Osmosis system. Please Follow the Startup Instructions. Startup Instructions Turn on the incoming cold water at the angle stop valve and the Step 1 Adapt-a-Valve. Check the system for leaks and tighten any fittings as necessary. (Check frequently over the next 24 hours to ensure no leaks are present).
Changing The Filter Cartridges Your RO module is equipped with valve heads which will automatically turn off the water supply to each filter when the filter is released, thus you do not need to turn off the incoming water supply at the Adapta-Valve. The RO faucet must be off when filters are replaced. To make the removal of the filter cartridges easier, the heads & cartridges may be swiveled up to 90 degrees as shown in the pictures below.
Annual Sanitization NOTICE Do not change your post-carbon filter until the sanitization has been completed. The pre-filters and membrane can be changed before the sanitization Step 1: Turn off the water supply to your RO system at the adapt-avalve and open the RO faucet to drain the storage tank. NOTICE DOSING SYRINGE WITH NO NEEDLE If you have connected your RO system to a refrigerator/ ice maker, make sure the connection has been turned off.
Check Air Pressure in the Tank NOTICE Check air pressure only when tank is empty of water! Check air pressure in the storage tank when you notice a decrease in available water from the RO system. Air can be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind the blue plastic cap. Step 1: Turn off the incoming water supply to the RO. Step 2: Open the RO Faucet and allow water to drain from the tank until it is completely empty.
TROUBLE SHOOTING Problem Cause Solution 1. Low/Slow Production Low Water Pressure Crimps in tubing Clogged pre-filters Fouled membrane Assure a minimum of 40 psi incoming water pressure. Premier sells a booster pump if home water pressure is low. Make sure water supply is turned on and feed water valve is all the way open. Check tubing and straighten or replace as necessary. Replace pre-filters. Replace membrane. 2.
TECHNICAL & WARRANTY INFORMATION Watts Premier 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381 RO-Pure System conforms to NSF Standard 58 for specific claims. GENERAL USE CONDITIONS: 1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system.
Arsenic Fact Sheet Arsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must be measured by an arsenic test kit or lab test. Public water utilities must have their water tested for arsenic. You can obtain the results from your water utility contained within your consumer confidence report. If you have your own well, you will need to have the water evaluated.
This page intentionally left blank Page 20
Service Record Model Number:__________ Serial Number:___________ Date of Purchase:__________ Date of Install:___________ Installed by:_____________ Date Sediment Filter (6 months) Carbon Pre-Filter (6 months) Membrane (2-5 years) NOTES: Page 21 Carbon Post-Filter (12months)
Limited Warranty WHAT YOUR WARRANTY COVERS: If any part of your Reverse Osmosis System is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, Watts Premier will repair or, at Watts Premier’s option, replace the system at no charge. HOW TO OBTAIN WARRANTY SERVICE: For warranty service, call 1-800-752-5582 for documentation and a return authorization number.