Specification Sheet

Series LFWDS
FloodSafe
®
Water Detector Shutoff
Sizes:
3
4" and 1" (20 and 25mm)
Series LFWDS Floodsafe
®
Water Detector Shutoff is a safety
valve that protects the home or business owner from cata-
strophic damage due to a water heater leak. The Series LFWDS
detects the presence of water on the floor (or in a drain pan)
beneath the water heater and automatically shuts off the water
supply and power source to the water heater. The LFWDS
features Lead Free* construction to comply with Lead Free*
installation requirements.
Features:
Testable and Resettable: The FloodSafe
®
Water Detector
Shutoff can be easily reset by the contractor, home or business
owner or plumbing inspector to assure proper operation
Lead Free* cast copper silicon alloy valve body construction
Easily installed on new or existing water heaters
No special piping is required
Supplied with a Water Dam for concrete, linoleum,
tile or other hard surface flooring
Sized for
3
4" or 1" (20 or 25mm) water supply lines
Secure interlocking connector cables are unique
to each connecting device
Powered by a safe low-voltage power supply that plugs into
a standard 120 VAC wall outlet and is wired using standard
thermostat cable (supplied by installer)
Employs state-of-the-art water detection technology
(no terminals to corrode or to impair operation)
Provides contacts for monitored alarm detection systems
Power Cutout Modules for the standing pilot gas fired water
heaters retain thermocouple circuit in the event of momentary
power outage
Mechanical
Maximum Pressure: 150psi (10.3 bar)
Maximum Temperature: 210°F (99°C)
Electrical
120 VAC, 70mA, 60Hz
Current draw: 50mA
Maximum Electric Water Heater current rating: 30A
Models
LFWDS-SP-L Standing Pilot - left-hand thread
LFWDS-SP-R Standing Pilot - right-hand thread
LFWDS-E220 Electric - 220 VAC
LFWDS-SI Spark Ignition/Oil Fired
Specifications
The contractor shall install an electronically actuated resettable
shutoff valve on the cold water supply of the water heater, as
indicated on the drawing.
The electronically actuated valve shall be a full flow valve that
closes upon detection of water at the water detector pad sup-
plied with the valve. Lead Free* valves shall be constructed using
Lead Free* materials. Lead Free* Water Detector Shutoff valves
shall comply with state codes and standards, where applicable,
requiring reduced lead content. A water detector pad shall be
installed on the floor beneath the water heater or in a drain pan
supplied by the contractor. The water detector pad shall be
supplied with an integral cable with connector to connect to the
valve control unit. The water detector pad shall be an electronic
sensing device.
The electronically actuated valve shall act to shut off both the
water supply and the power to the water heater simultaneously
upon detection of water.
A visual and audible indication of actuation shall be initiated and
normally open contacts suitable for connection to remote moni-
tored alarm actuation shall close.
LFWDS-SP-L
For Residential and Commercial Applications
ES-LFWDS
Job Name
–––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
Job Location
–––––––––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Engineer
–––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No.
––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Representative
––––––––––––––––––––––––––––––––––––––––
LEAD FREE
*
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
*The wetted surface of this product contacted by consumable
water contains less than 0.25% of lead by weight.
NOTICE
Inquire with governing authorities for local installation requirements
The information contained herein is not intended to replace the full
product installation and safety information available or the experience
of a trained product installer. You are required to thoroughly read all
installation instructions and product safety information before begin-
ning the installation of this product.
NOTICE