Manual

Series FV-4M1
Automatic Air Vent Valves
Sizes:
1
8" – 1" (3 – 25mm)
Series FV-4M1 Automatic Air Vent Valves provide automatic air
venting for hot or cold water distribution systems. These vents
purge air that may be in the water system.
The vent valve utilizes a float to actuate the valve plug which is
located at the top of the valve. Once the air is displaced and
the system pressure is sustained, the valve plug seals and pre-
vents any water from escaping from the system.
The float vent can also operate as an anti-vacuum device since
it will permit air to enter the system when it must be drained. It
can also be installed to permit the separation and dispersal of
air while fluid is actually circulating in the system.
Features
Body and cover are brass construction
•Air vent with silicone rubber seal
•Impurities do not usually affect function as maximum float line
of water is always lower than the valve seal
Float is high temperature resistant polyethylene
Suitable for use with glycol systems
•Can be disassembled for inspection and cleaning
Pressure – Temperature
Minimum working pressure: 1.45psi (10 kPa)
Maximum working pressure: 150psi (10 bars)
Temperature Range: 33˚F – 240˚F (5˚C – 116˚C)
For Hydronic Heating Applications
ES-FV-4M1
Job Name
–––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
Job Location
–––––––––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Engineer
–––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No.
–––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Representative
––––––––––––––––––––––––––––––––––––––––
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Vacuum
Breaker
Float
Specifications
Air vent shall have brass body & cover and silicone rubber
seal. Float shall be constructed of high temperature resistant
polyethylene and shall be for use with glycol systems. Air vent
shall be Watts Regulator Company Series FV-4M1.
Venting Air
Float
Silicone
Seal
Float
Collar
Spring Loaded
Lever
(Air)
Vacuum
Breaker
Diagram above shows the quantity of air vented by the “Float
Vent” according to the pressure in the system.
1
/2
" – 1"
1
/8
" –
1
/4
"

Summary of content (2 pages)