Use and Care Manual

1
2
3
1a
1b
4
4. Feed the toggle bolt and tubes
through the mounting hole in
the sink. Test t faucet
placement.
5. Peel the white backing paper
off the seal on the bottom of the
faucet base and press rmly
over the mounting location.
6. Using a Phillips screwdriver
torque the toggle bolt through
the spout hole to 5lbs/in.
5
A 1.25” Mounting hole is
required for faucet installation.
6
Manual # 199017
Date 08/17/11
Connect tubes to the RO faucet * Mount the RO faucet
Install Spout and Pull Battery Tab *
This RO faucet is
equipped with quick
connect ttings for
easy tube
installation.
To connect tubes,
simply push them
rmly into their
corresponding
tting on the RO
faucet until fully
seated.
1. Connect 3/8” BLUE
drinking water tube.
(3/8” Fitting on Toggle Bolt)
To disconnect a
tube, push in collet
(Fig. 1a) squarely
against face of
tting (Fig. 1b).
With collet held
in this position the
tube can be
removed.
2. Connect 3/8” BLACK
tube from drain saddle.
(3/8” Fitting on base of faucet)
3. Connect 1/4” RED
tube from lter system.
(1/4” Fitting on base of faucet)
Note:
The RO Faucet drinking
water tube tting is 3/8”.
If your system uses a 1/4”
tube you will need a
1/4”-3/8” adapter.
Approximately 3/4”
of the tube should go
into the tting.
* NOTE: Step 2 & 3 for air gap applications only!
* NOTE: Step 8 for monitored faucets only!
8. Pull the Battery Safety Tab out
to activate faucet monitor.
Make sure that the clear
drawer is rmly seated in the
faucet base. The monitor will
ash briey once activated.
7. Insert spout into the faucet
base until fully seated.
“This product contains a
button cell battery. If
swallowed, it could cause
severe injury or death in
just 2 hours. Seek medical
attention immediately.”
CAUTION!
8
7

Summary of content (1 pages)