Instructions / Assembly

IS-LFTWHG2-FT/FS
Installation Instructions
Series LFTWHG2
Tankless Water Heater Valves with
VersaFit™ Technology
Sizes:
3
4" Service Valve Set
ATTENTION INSTALLER: After installation, please leave
this Instruction Sheet for occupant’s information.
IMPORTANT: Inquire with governing authorities for local
installation requirements.
Fig.4
STOP!
Before connecting any components, be sure to read all
of the tankless water heater manufacturer’s installation
instructions. Failure to follow instructions below can re-
sult in serious injury, death and/or property damage.
1. Identify all components and
orientations before beginning
installation
1. HOT WATER SERVICE VALVE (Fig.1)
Identified by the red handle insert.
2. COLD WATER SERVICE VALVE (Fig.2)
Identified by the blue handle insert.
3. PRESSURE RELIEF VALVE (Fig.3)
Identified by a silver test lever.
Note: ANSI Z21.22 and local codes
govern the installation of pressure
relief valves.
2. Before attaching any components
to the tankless water heater,
attach PRESSURE RELIEF VALVE
to HOT WATER ISOLATION
VALVE (Figure 4)
CAUTION
!
Do not over tighten
relief valve. Do not tighten more
than one full turn past hand tight.
a. Apply thread sealant to the exposed
threads of the pressure relief valve.
b. Thread the pressure relief valve into
the
3
4" port on the side of the hot
water valve and hand tighten. Using
a wrench, tighten the pressure relief
valve until the discharge on the pres-
sure relief valve is positioned down-
ward on the isolation valve, as shown
in Figure 4.
Drain Line
Attach this end to
tankless water heater
Attach this end to
tankless water heater
3. Install COLD WATER SERVICE VALVE onto cold water
inlet of tankless water heater
a. Locate the cold water threaded inlet on the tankless water
heater and apply thread sealant to the threads.
b. Slightly loosen the union nut on the top of the cold water
valve so that the union tailpiece rotates freely.
c. Holding the cold water valve beneath the cold water inlet,
thread the union tailpiece onto the inlet and hand tighten.
Using a wrench, tighten the union tailpiece. Next, position
the cold water valve with the purge port pointing forward,
towards the front of the water heater, and hand tighten the
union nut.
d. Tighten the union nut with a wrench, making sure that the
valve does not rotate out of position.
4. Install HOT WATER SERVICE VALVE onto hot water
outlet of tankless water heater
WARNING
!
There should not be a shutoff located
between the tankless water heater and pressure relief
valve. (See direction arrow in Fig. 5.)
a. Locate the hot water threaded outlet on the tankless water
heater and apply thread sealant to the threads.
b. Slightly loosen the union nut on the top of the hot water
valve so that the union tailpiece rotates freely.
c. Holding the hot water valve beneath the hot water outlet,
thread the union tailpiece onto the outlet and hand tighten.
Using a wrench, tighten the union tailpiece. Next, position
the hot valve with the purge port and pressure relief valve
pointing forward, towards the front of the water heater, and
hand tighten the union nut. Tighten the union nut with a
wrench, making sure that the valve does not rotate out of
position.
Fig.1
Fig.2
Fig.3
TWHG2
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
For valves with CPVC or PEX end connections do not exceed the
tubing manufacturers pressure and temperature ratings. Refer to the
tubing manufacturers product specifications for that information.
WARNING
!

Summary of content (4 pages)