How to use the Quick-Connect fittings on the RO Module
To make a connection, the tube is simply pushed into the fitting.
Place a piece of tape
1
/2" from end of tube to indicate how far the
tube should be inserted. The unique patented Quick-Connect
locking system holds the tube firmly in place without deforming it or
restricting flow.
Cut the tube square. It is essential that the outside diameter be free of score marks
and that burrs and sharp edges be removed before inserting into fitting.
Fitting grips before it seals. Ensure tube is pushed into the tube stop.
Push the tube into the fitting, to the tube stop. The collet (gripper) has stainless
steel teeth which hold the tube firmly in position while the O-ring provides a perma-
nent leak proof seal.
Pull on the tube to check that it is secure. It is a good practice to test the system
prior to leaving site and /or before use.
To disconnect, ensure the system is depressurized before removing the tube. Push
in collet squarely against face of fitting. With the collet held in this position, the tube
can be removed. The fitting can then be reused.