Instructions / Assembly
5
Adapt-A-Valve™ Installation
Caution: Water supply line to the system must be from the cold
water supply line only. Hot water will severely damage your
system.
Configuration for
1
⁄2 inch valve
(using no brass fittings)
Figure 1
Configuration for
3
⁄8 inch valve
(using brass fittings)
Figure 2
Placement diagram for Adapt-A-Valve™
Figure 3
Step A – Turn off the hot and cold water supply to the faucet by
turning the angle stop valves off.
Step B – Remove water supply line from faucet to the angle stop
valves.
Step C – Attach the Adapt-A-Valve™ as illustrated in Fig 2, Fig 3,
choosing the configuration that fits your plumbing needs
Step D – Re-attach the water supply line to the fittings attached to
the angle stop valves.
Step E – Completed Valve installation Figure: 3.
Step F – Insert Green tube into cold water Adapt-A-Valve™ until it
stops.
Step G – Insert Black tube into hot water Adapt-A-Valve™ until it
stops.
Caution: Water supply line to the system must be from the cold
STEP 3
Figure 1
Figure: 2
Figure: 3
Hot
Supply
Cold
Supply
STEP 4
Reverse Osmosis Module Mounting
Step A – Determine best location for the
RO module to be mounted to
allow for future system main-
tenance. The parts bag has 2
self-tapping screws. Using an
electric drill with a Phillips bit,
screw them into the cabinet
wall 6" apart and 16" from the
bottom of the cabinet.
Note: Do not cut any RO system tubes at this time
STEP 2
Watts Chrome Top Mount
Faucet Installation
Gather and identify the faucet pieces.
Step A - Remove faucet base and faucet spout from their respective
plastic bags. From above the sink, feed the faucet tubing
& toggle bolt down through the 1¼" mounting hole in the
sink. Ensure that the soft rubber gasket has the protec-
tive white paper removed from both sides and is uniformly
positioned in between the base of the faucet and the top of
the sink.
Step B - Align the faucet base so that the handle is on the right side
and the base is sitting flush on the sink top. Using a phillips
head screwdriver, turn the screw located down the hole
where the spout will be installed, clockwise until the toggle
bolt secures the faucet base snug onto the sink top.
Step C - Once the faucet base is securely fastened to the sink top,
insert the faucet spout into the faucet base until it is fully
seated. Turn the handle up (away from you) to the “OFF”
position.
Step D - Connect the loose end of the
3
⁄8" blue plastic tubing from
the faucet to the
3
⁄8" plastic fitting from the final inline filter.
MINIMUM MAXIMUM
Mounting Hole Size 1" 1
1
⁄4"
Torque on Toggle Bolt 5 lb.in. (max)