Congratulations!
You have completed the installation of your new Reverse Osmosis system.
Please Follow the Startup Instructions.
Flushing of the tank 3 times is only necessary during the initial startup and after replacing
the membrane.
Note:
Start up Instructions
Step 1 Turn on the incoming hot and cold water angle stop valves.
Turn both of the adapt-a-valves on and check the system for leaks and tighten ttings
as necessary.
Note: Check daily over the next week
to ensure no leaks are present.
Step 2 Plug the (24 volt) transformer
power cord connector into the
ESOV as pictured.
Step 3 Plug the transformer into the
electrical outlet under the sink.
Step 4 Ensure ball valve on tank is open.
Step 5 Open the RO faucet and leave it
open until water begins to drip.
Then close the faucet.
The tank will take between 2 - 4
hours to ll.
Note: If no water comes out of the RO
faucet after a few minutes check
the power outlet! It is possible that the power outlet you used for the RO unit
is controlled by the garbage disposal switch. To test - Unplug the garbage
disposal and ip the garbage disposal switch to “on” . If the RO pump turns on
and water starts to drip out of the RO faucet you will need to connect the system
to a different power outlet socket.
Step 6 After the tank has lled once, open the RO faucet and drain the tank.
Note: Water may be cloudy or milky due to air in the system and carbon particles ushing out
of the nal polishing lter. This condition will resolve itself after ushing a couple of
tanks of water.
Step 7 Complete step #6 two more times. The process of ushing the system rst three times
should take about one day to complete. The fourth tank can be used for drinking water.
Warning: To prevent the possibility of electrical shock, clean up any water on
cabinet oor and dry all water from outside of RO unit.
ESOV