SPEEDCOM SC5800 User Manual
24
4.1 Customer Furnished Tools and Equipment
The following table lists tools and equipment required to install the SC5800 system.
General, IU-to-OU Interconnect
Cable cutting and stripping tools.
Earth lug crimp tools.
3 mm flat screwdriver - IU to OU power cable.
RJ45 crimp tool - IU to OU data cable.
Earth cable or strap rated at 45A with 5 mm earth lug earthing the Indoor and
Outdoor Units.
Cable ties, used to secure the cables to the mast at regular intervals.
IU
Pozi #2 screwdriver - IU mounting in a 19" rack and the earth lug.
2.5mm Allen key - To change the position of the IU mounting brackets.
DC power supply cable: minimum 2.5 mm square conductor, rated for 10 A. For
connection between the power supply and the Indoor Unit DC connector on the
rear panel.
IU earth lug: 10-4 (10 square mm for wire and hole big enough for M4 thread)
OU
13 mm spanner (or Wrench) – used for attachment of OU to mounting bracket.
13 mm spanner - used for attachment of OU mounting bracket to pole.
2.5 mm Allen key - used to tighten OU connection box cover fasteners.
OU earth lug: 10-8 (10 square mm for wire and hole big enough for M8 thread)
For details on the data and RF cables, which are also customer furnished
equipment, see Section 7, Maintenance Information, page 57.