User Manual

SPEEDCOM SC5800 User Manual
46
6.5.1.1.2 T1 Port Line Code
Default setting is B8ZS. However, it can be set to either B8ZS or AMI.
6.5.1.2 Payload Error Monitoring
Term Name Description
AIS Alarm Indication
Signal
This is an all 1’s detection, incoming to the
equipment on the payload tributaries. Note that
there is independent monitoring for AIS on each of
the 4 tributaries.
LOS Loss of Signal This is a loss of signal detected on the input to the
payload data port tributaries. Note that there is
independent monitoring for LOS on each of the 4
tributaries.
6.5.1.3 Service Channel Port
The service channel serial port provides a means to send asynchronous data across
the link to the far side service channel port. Service channel ports can be connected
back-to-back (i.e., Remote to Local) at a remote site so as to extend the channel in
a multi-hop network. The service channel data is multiplexed with IP data onto the
RF overhead link. Priority is given to IP data.
Use the Load Defaults option or change to the required settings and then
use the Apply Changes button.
Use the Exit button to exit without any changes being made.
6.5.1.3.1 Baud Rate
Default setting is 115200 bit/s (Ver 1, 2).
6.5.1.3.2 Data Width
Default setting is 8 bits.
6.5.1.3.3 Parity
Default setting is None.
6.5.1.3.4 Flow Control
Default setting is None.
6.5.1.3.5 Stop Bits
Default setting is 1 Bit.
6.5.1.4 Relay Scripting (NA for Version 2 releases)
Note: THIS MANUAL ADDRESS FEATURES SPECIFIC TO VERSION 2 OF THE
SPEEDCOM SC5800 PLEASE IGNORE REFERENCES TO OTHER VERSIONS.