The following table lists information to assist the user to select cables to be used
between the Indoor and Outdoor Units.
Interconnecting cable
Data
General Requirements
STP (FTP) 4 Pairs Solid Cat 5, PVC FR UV protected Polifin H2/J263/904
Outer Black. Outer diameter of cable: 7.3mm ± 0.5mm. (This is an
“upjacketed” STP 4 Pair cable.)
This is a standard FTP
Cat 5 cable that is
‘upjacketed’ with suitable
plastic for FR/UV (Flame
retardant/Ultra Violet)
protection.
Examples:
1. Mohawk CAT5 P/N 57041
2. Superior Essex BBDN CAT 5 cable P/N 04-0010-34 (7.8mm)
3. Superior Essex CAT 5 P/N 18-241-31 18-241-11 (5.1mm)
4. General Cable CAT 5 P/N 2137113 2137114 (5.6mm)
5. Belden CAT 5 P/N BC1002 (6.0mm)
For the cables that have diameters less the required OD, one can use one
or two pieces of heatshrink on the cable where it passes through the
gasket.
Interconnecting cable
Power
General Requirements
Power 1.5mm sq stranded PVC Insulated, PVC FR UV protected Polifin
H2/J263/904 Outer Black 300/500V Temp -20°C to +85°C. Cable outer
diameter: between 7.4mm and 9mm i.e. 8.2mm ± 0.8mm.
Examples:
Superior Essex type SJOOW flexible cable P/N 441821* (7.4mm)
Carol Cable (General Cable) SJOW/SJO P/N 02001 18 gauge 2 conductor
(7.8mm)