Object ID Group Object Type Access Description
1.3.6.1.4.1.1316.1.1.1.1.4.6
mdrmteScc2FullCnt COUNTER read-only Indicates the total number of
times SCC2 was full to capacity
1.3.6.1.4.1.1316.1.1.1.1.4.7 mdrmteScc1UnderrunCnt COUNTER read-only Indicates the total number of
times SCC1 ran out of BDs
1.3.6.1.4.1.1316.1.1.1.1.4.8
mdrmteScc2UnderrunCnt COUNTER read-only Indicates the total number of
times SCC2 ran out of BDs
1.3.6.1.4.1.1316.1.1.1.1.4.9
mdrmteScc2RxBdAbortCnt COUNTER read-only Indicates the total number of
times SCC2 received an
aborted frame
1.3.6.1.4.1.1316.1.1.1.1.4.10 mdrmteScc2RxBdNonOctCnt COUNTER read-only Indicates the total number of
times SCC2 received a Non
octet aligned frame
1.3.6.1.4.1.1316.1.1.1.1.4.11 mdrmteScc2RxBdCrcCnt COUNTER read-only Indicates the total number of
times SCC2 received
1.3.6.1.4.1.1316.1.1.1.1.5 mdrmteResetAllPerfData INTEGER write-only Reset all parameters associated
with Packet Error and G.826
measurements for the RF Link.
1.3.6.1.4.1.1316.1.1.1.2 mdrmteConfiguration
1.3.6.1.4.1.1316.1.1.1.2.1 MdrmtePayloadConf
1.3.6.1.4.1.1316.1.1.1.2.1.1 MdrmteDataRate INTEGER read-write Configure the tributary data
interface rate - either E1 or T1.
1.3.6.1.4.1.1316.1.1.1.2.1.2 mdrmteLineCodeType INTEGER read-write Defines the line code types for
the tributaries, either HDB3 or
AMI for E1 tributaries or B8ZS
or AMI for T1 tributaries.
1.3.6.1.4.1.1316.1.1.1.2.1.3 mdrmtePcTable SEQUENCE
1.3.6.1.4.1.1316.1.1.1.2.1.3.1 mdrmtePcEntry SYNTAX
1.3.6.1.4.1.1316.1.1.1.2.1.3.1.
1
mdrmtePcIndex INTEGER
1.3.6.1.4.1.1316.1.1.1.2.1.3.1.
2
mdrmtePcLabel DisplayString read-write E1/T1 Payload configuration
tributary label.
1.3.6.1.4.1.1316.1.1.1.2.1.3.1.
3
mdrmtePcActive INTEGER read-write Defines whether tributaries are
active or inactive.
1.3.6.1.4.1.1316.1.1.1.2.2 mdrmteRFLinkConf
1.3.6.1.4.1.1316.1.1.1.2.2.1 mdrmteTxPower INTEGER read-write Allows setup of the output power
available at the diplexer port of
the Outdoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.2.2 mdrmteBandPlan INTEGER read-write The SC5800 Outdoor Units
operate in the 5.725 GHz to
5.850 GHz ISM frequency band.
The SC5800 has predefined
frequency channel plans
(termed A, B, C and D). Refer
to the User's manual for details
on defined frequencies.
1.3.6.1.4.1.1316.1.1.1.2.2.3 mdrmteTxFrequencyPlanD INTEGER read-write Frequency plan D allows
independent control of transmit
and receive frequencies. This
enables a very flexible
frequency plan and can be used
to overcome interference in the
5.8 GHz ISM band. The
frequencies that can be used in
the lower or upper sub-bands
can be selected in 1 MHz
increments. Performance