Object ID Group Object Type Access Description
memory - limited to 14
characters in length.
1.3.6.1.4.1.1316.1.1.1.2.4.2 mdrmteIUSerialNumber DisplayString read-only An electronic serial number is
read from the Indoor Unit - this
number is unique for each IU
and is derived from an IC that
is used within the product.
1.3.6.1.4.1.1316.1.1.1.2.4.3 mdrmteIUFirmwareVersion DisplayString read-only The Indoor Unit firmware
version is the version of
application firmware that loaded
into the product's application
Flash.
1.3.6.1.4.1.1316.1.1.1.2.4.4 mdrmteIUBootkernelVersion DisplayString read-only The Indoor Unit bootkernel
version is the version of boot
firmware that loaded into the
product's Boot Flash.
1.3.6.1.4.1.1316.1.1.1.2.4.5 mdrmteOUSerialNumber INTEGER read-only The Outdoor Serial Number is
programmed into the OU at time
of manufacture and is read via
the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.4.6 MdrmteOUPICFirmwareVersion DisplayString read-only The Outdoor Unit PIC firmware
number is programmed into the
OU at time of manufacture and
is read via the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.4.7 mdrmteOUPayloadSupport INTEGER Deprecated.
1.3.6.1.4.1.1316.1.1.1.2.4.8 mdrmteDate DisplayString read-write This is a date record that is
recovered from the Indoor
Unit's Real Time Clock.
1.3.6.1.4.1.1316.1.1.1.2.4.9 mdrmteTime DisplayString read-write This is a time record that is
recovered from the Indoor
Unit's Real Time Clock.
1.3.6.1.4.1.1316.1.1.1.2.4.10 mdrmteNOVRAMInit INTEGER read-write If activated, the Nonvolatile
memory is initialised to a set of
default parameters.
1.3.6.1.4.1.1316.1.1.1.2.4.11 mdrmteFECBypass INTEGER read-write This is primarily a laboratory
test entry used to control
whether the FEC circuitry within
the Indoor Unit is activated. By
default the FEC is not
bypassed i.e. FEC is active.
1.3.6.1.4.1.1316.1.1.1.2.4.12 mdrmteFECCorrectableSymbols INTEGER read-write This is primarily a laboratory
test entry used to control the
FEC correction power - 20 parity
symbols are appended to the
transmit packet - 10 is the
maximum number of symbols
the FEC circuitry can correct.
At a maximum, 20 symbols in
error can be detected but only
10 can be corrected - the higher
the correction power selected,
the greater the improvement in
system gain.
1.3.6.1.4.1.1316.1.1.1.2.4.13 mdrmteTribCode DisplayString read-write This is a text entry code (16
characters) used to allow
activation of tributaries on the
Indoor Units. It is unique to the
Indoor Unit based on a
hardware-dependent serial
number in the IU.
1.3.6.1.4.1.1316.1.1.1.2.4.14 mdrmteIndoorUnitBarCodeNumber DisplayString read-write This is a text entry code used to