User's Manual

WaveIP Ltd. GigAccess™ OFDM 5.8
Pa
g
e 16 of 41
2
2
.
.
4
4
.
.
5
5
C
C
a
a
b
b
l
l
e
e
s
s
Straight CAT5 Gauge 24-shielded outdoor rated cable must be installed between
Outdoor Unit and Indoor Outlet. It should be UV resistant and flame retardant. The
cable should be UL listed
and contain at least 4 twisted pairs.
The outdoor cables scheme is given in Appendix F
Outdoor Cable Scheme.
The Indoor Outlet side and Outdoor Unit side will crimped with RJ-45 tool.

























CAT5 cable must not exceed 300 feet (91 meters).



































































Use a suitable primary protector in accordance with article 800 in the NEC, if the
exposed part of the CAT5 cable exceeds 140 feet (42 meters). Requirements of NEC
articles 725 and 800 for the appropriate wiring methods during cable installation,
shall be satisfied.










































The Outdoor Unit side will be assembled by the following list (Figure
2-4):
Insert seal bracket (grommet clamping plate) on the cable.
Insert rubber seal (grommet) on the cable.
Crimp the RJ-45 Plug.
Figure 2-4: Cable preparation for Outdoor Unit
Insert the RJ-45 to the Outdoor Unit (Figure
2-5).
Insert NC-6 screws with spring washer to the seal bracket.