WaveIP Ltd. GigAccess™ OFDM 5.8
Pa
g
e 30 of 41
Point-to-Point operation
Antenna Gain TX power EIRP Safe Distance Sector
Type
[dBi] [Numeric] [dBm] [mW] [dBm] [mW] [cm]
22 199.53 26 398.1 48 63095 70.8 p2p
Table 7-2: Hazard Distance for Point to Point
When using the system for point-to-point
applications, all outdoor units must be
installed with a separation distance of at least 2 meters from all persons during
normal operation.