User's Manual

WaveIP Ltd. GigAccess™ OFDM 5.8
Pa
g
e 38 of 41
The Advanced window contains the following fields:
General Configuration:
" Admin Login Password – Set the “Administrator” password for Admin login
.
" User Login Password – Set the “User” password for User login.
" AU-SU Max Distance – Set the distance of the farthest SU.
Ethernet Configuration:
" Ethernet Switch Port 1 Configuration – set the speed and duplex of port 1.
Available values are: 10M Full Duplex, 100M Full Duplex and Auto-Negotiation.
" Ethernet Switch Port 2 Configuration – set the speed and duplex of port 2.
Available values are: 10M Full Duplex, 100M Full Duplex and Auto-Negotiation.
" Enable Ethernet Switch Security – when this flag is set, traffic between Port 1
to Port 2 is blocked (VLAN).
NOTE: GigAccess unit Ethernet port and the other end Ethernet port (Router,
PC etc.) need to be set to same speed (both sides AUTO, 100 Full or 10 Full).
Fail to do so may cause Ethernet packet lost.
Power Control – ATPC (AU only):
" Activate ATPC – Check this box to activate ATPC.
" Expected Rx power – Set the desired Rx power (expected RSSI at the AU).
Tx Power Configuration:
" Antenna Gain – select the antenna gain.
" Cable Loss - Insert cable attenuation for the specific frequency used.
" TX Power – Select the output power at the antenna connector (Admin user
only). Changes of the Tx Power must be done by an Expert Technician. This
TX Power value is limited by the Tool set according to the type of the antenna
used in order to ensure that the power at the output of the antenna stands in
the selected regulation restrictions.
Regulation:
" Select the appropriate regulation (FCC, ETSI, no regulation).
Link Type:
" Set the link type (p2p, p2mp). This field is not relevant for 900 MHz.
GPS Synchronization:
" AU Synchronization / External Sync – Available values are: Enable or Disable.
If an external clock (from GPS or AU) is used to synchronize the AU select
Enable, otherwise select Disable.
" AU Synchronization / Master/Slave – This field is relevant only if External Sync
is Enabled. Select Master when the AU acts as the master unit, which produces
the synchronization clock to all other AUs (Slaves). At any time only one
master exists. The slave unit are synchronize to the Master clock.
" Signal Count – Shows running number for synchronization input pulses.
Running counter indicates synchronization is active.