SUCCESS is followed by a block of information in the format shown
below:
WN_GET_PROFILE_LIST Response Format:
Number of profiles (n) [1 byte]
Active profile number [1 byte]
Profile Name 1 (up to 24 byte null terminated string)
Profile Name 2 (up to 24 byte null terminated string)
.
.
.
Profile Name n (null terminated string) [24 bytes]
Where:
Number of profiles: Unsigned byte giving the current number of
profiles in configuration sector. The number
of profiles may change.
Active profile number: Unsigned byte giving the number (or index) of
the currently active profile.
Profile name: Null terminated string of 24 bytes of length
(the string may be shorter than the 24 bytes as
long as it is followed immediately by the null
termination character). The 24 bytes do not
include the null termination character.
q NCL Label Values
Please note the following additions/clarifications to the NCL Label
Values Table:
CMND ASCII 'A'
RESP ASCII 'C'
SUCCESS ASCII '1'
VENDOR ASCII 'Z'
VEND_MOTOROLA ASCII '0'
VEND_WAVENET ASCII 'F'
WN_GET_STATUS ASCII '?'
WN_GET_RADIO ASCII 'r ' (eg NCL command ZF?r)
WN_GET_BATT_VOLT ASCII 'v' (eg NCL command ZF?v)
WN_GET_TIME ASCII 't' (eg NCL command ZF?t)
WN_GET_SETTINGS ASCII 'u' (eg NCL command ZF?u)
WN_GET_SERIAL ASCII ‘s’ (eg NCL command ZFts)
WN_SET_PARAM ASCII ‘^’ (eg NCL cmd ZF^\04\00\00\01\09)
WN_GET_PARAM ASCII ‘$’ (eg NCL commandS ZF$..)
WN_PWR_SAVE_MODE 0x7000 (eg NCL cmd ZF$\70\00 = ZF$p\00)
WN_PROFILE 0x6600 (eg NCL cmd ZF$\66\00 = ZF$f\00)
WN_MSG_RX_NOTIF_TMR 0x6E00 (eg NCL cmd ZF$\6E\00 = ZF$n\00)
WN_CMD ASCII '*' (eg NCL commands ZF*..)