User's Manual
Table Of Contents
- Introduction
- The Integrator’s Task
- Installing the Modem
- Using the Modem Test Jig
- Testing
- Desense
- Application Development
- Message Routing and Migration
- Appendix A - NCL Interface
- Appendix B - Software Development Kit
- SDK Contents
- System Requirements
- SDK Software Architecture
- NCL Application Programmer’s Interface
- Implementation
- Logical Architecture
- Application Interface
- Opening a Session
- Close Session
- Send Data to a Radio Host
- Receive Data From RPM
- Get RPM Status Information
- Set Configuration ITEMS Within the RPM
- Reset RPM
- Register Event Callback Function
- Enable / Disable Events
- Get Error Description
- Register Wakeup Application
- Deregister Wakeup Application
- Switch RPM On/Off
- Send Generic NCL Command To RPM
- Get Software Version
- SCR Application Programmer’s Interface
- A
- Appendix C – Sample programs
- Appendix D - Wavenet Application Loader
- Appendix E - Numeric Conversion Chart
- Appendix F - Specifications
- Appendix H - Glossary
SDK SCR-API ______________________________________________ Boomer II User Manual & Integrator’s Guide
Wavenet Technology 160 BM210012WT27
Shown here are several examples of possible output from the
scr_Print() function:
FROM_NET Message
The FROM_NET message is printed as an OB message for a DataTAC
4000 network.
*** OB message ***
LLI 80051234
Data header - BB1
Data –
0 54 68 69 73 20 69 73 20 73 6F 6D 65 20 64 61 74 This is some
10 61 2E data.
For DataTAC 5000 and DataTAC 6000 networks, a FROM_NET
message is printed as an MI message.
*** MI message ***
LLI 80051234
Data header - BB1
Data –
0 54 68 69 73 20 69 73 20 73 6F 6D 65 20 64 61 74 This is some
10 61 2E data.
TO_NET Message
*** TO_NET message ***
LLI 87654321
Save bytes – AA
Acknowledgment - SCR_TONET_ACK_REMOTE
Data header - BB1
Data –
0 54 68 69 73 20 69 73 20 73 6F 6D 65 20 64 61 74 This is some
10 61 2E data.
ACK Message
For DataTAC 5000 or DataTAC 6000 networks, an ACK message is
printed as an HC message.
*** HC message ***
LLI 87654321
Save bytes – AA
Response - 78 - MT out of range or powered off
For the DataTAC 4000 network, an ACK message is printed as an AB
message.
*** AB message ***
LLI 87654321
Save bytes – AA
Response - 78 - No response from wireless device