User's Manual
Table Of Contents
- Introduction
- The Integrator’s Task
- Installing the Modem
- Using the Modem Test Jig
- Testing
- Desense
- Application Development
- Message Routing and Migration
- Appendix A - NCL Interface
- Appendix B - Software Development Kit
- SDK Contents
- System Requirements
- SDK Software Architecture
- NCL Application Programmer’s Interface
- Implementation
- Logical Architecture
- Application Interface
- Opening a Session
- Close Session
- Send Data to a Radio Host
- Receive Data From RPM
- Get RPM Status Information
- Set Configuration ITEMS Within the RPM
- Reset RPM
- Register Event Callback Function
- Enable / Disable Events
- Get Error Description
- Register Wakeup Application
- Deregister Wakeup Application
- Switch RPM On/Off
- Send Generic NCL Command To RPM
- Get Software Version
- SCR Application Programmer’s Interface
- A
- Appendix C – Sample programs
- Appendix D - Wavenet Application Loader
- Appendix E - Numeric Conversion Chart
- Appendix F - Specifications
- Appendix H - Glossary
Boomer II User Manual & Integrator’s Guide __________________________________ APPENDIX F - Specifications
BM210012WT27 177 Wavenet Technology
Appendix F - Specifications
Physical Properties
Weight < 50g
Size (L x W x H) 70mm x 52mm x 9mm
Communication Protocols
Modem to radio network protocol RD-LAP 3.1, 3.2, 3.3 and MDC 3.3
Modem to terminal (e.g. handheld) protocol NCL 1.2
Environmental Conditions
Operating temperature
-30°C to +60°C
Storage temperature
-40°C to 70°C
Relative Humidity 0 to 95%
Ports
Data Interface Port TTL compatible serial port,
9600 baud
RF Connector
MMCX female, 50Ω.
Straight connection or right angle
LED Indicators
Power Green flashes when scanning
On, when locked
Off, when the Boomer II is off
Transmit Red flashes when transmitting
Receive Green flashes when receiving
Power
Voltage 3.8V nominal
(3.4 to 4.2V range)
Transmit < 1.6 A (2.2 A if mismatched antenna)
Receive < 85 mA
Standby < 4.4 mA
(Add 1.2 mA if LED’s enabled)
Off current consumption 100 µA (nominal)
Transmit Duration 32 ms (minimum)
7 seconds RD-LAP (maximum)
30% (maximum) Duty Cycle
Power Supply Ripple < 15 mV peak to peak