User's Manual
Table Of Contents
- Introduction
- The Integrator’s Task
- Installing the Modem
- Using the Modem Test Jig
- Testing
- Desense
- Application Development
- Message Routing and Migration
- Appendix A - NCL Interface
- Appendix B - Software Development Kit
- SDK Contents
- System Requirements
- SDK Software Architecture
- NCL Application Programmer’s Interface
- Implementation
- Logical Architecture
- Application Interface
- Opening a Session
- Close Session
- Send Data to a Radio Host
- Receive Data From RPM
- Get RPM Status Information
- Set Configuration ITEMS Within the RPM
- Reset RPM
- Register Event Callback Function
- Enable / Disable Events
- Get Error Description
- Register Wakeup Application
- Deregister Wakeup Application
- Switch RPM On/Off
- Send Generic NCL Command To RPM
- Get Software Version
- SCR Application Programmer’s Interface
- A
- Appendix C – Sample programs
- Appendix D - Wavenet Application Loader
- Appendix E - Numeric Conversion Chart
- Appendix F - Specifications
- Appendix H - Glossary
Boomer II User Manual & Integrator’s Guide _________________________________________________Installation
BM210012WT27 37 Wavenet Technology
Serial Communications Interface Definitions
J1
Pin #
Signal Description Signal Active State
1
DCD
Data Carrier Detect Output Low when modem in-range
2
RXD
Receive Data Output Low when active
3
TXD
Transmit Data Input Low when active
4
DTR
Data transmit ready Input Low when ready
6
DSR
Data set ready Output Low when ready
7
RTS
Request to send
Input High when host requires data
throttling
8
CTS
Clear to send
Output High when modem requires
data throttling
9
RI
Ring indicator
Output Pulses Low when messages
are waiting
Status Input / Output lines
Note: Not currently supported but may be added in future releases.
The status lines (SS0 to SS3) may be software configured for bi-
directional operation. Each line has a 100kΩ pull-up resistor, 33Ω
series resistor and clamp diode to the internal supply line for
protection. The electrical interface capability, equivalent circuit and
operation of these lines is summarized in the tables below:
Status Input/Output Equivalent Circuit
Status Input/Output Electrical Characteristics
Parameter Range Low High
Input Voltage 0-3.3 V
OR
0-5V 0.8 V (max) 2.5 V (min)
Output Voltage 0 – 3.3 V 0.5 V (max) 2.3 V (min)
Input Current 100 µA (max) 100 µA (max)
Output Current 3.2 mA (max) 1.6 mA (min)