Installation_________________________________________________ Boomer II User Manual & Integrator’s Guide
Wavenet Technology 44 BM210012WT27
The algorithm for the Source Based Time Averaging transmit control
and the relevant parameters are given below:
Idle_Time = Duty_Factor * Transmit_Duration
Duty Factor = (100 – Duty_Cycle%) / Duty_Cycle%
Duty_Cycle% = Preset limit for SAR compliance
Source Based Time Averaging Transmit Algorithm
The Boomer-II modem module has an overall transmit Duty Cycle
limitation of 30% (maximum) to physically protect the modem
hardware.
The default Duty Cycle preset in the factory at the time of manufacture
is 10%. Other duty factors and SAR evaluation must be addressed at
the time of OEM integration into any final host product and is the
responsibility of the OEM Integrator.
The algorithm and preset Duty Cycle is recorded in the module
firmware at the time of manufacture and cannot be altered by the end
user.
No
Yes
No
Wait for data
Decrement
Idle_Time
Transmit data
Determine actual
Transmit_Duration
Buffer data
Decrement
Idle_Time
Yes
Has the transmit
Idle_Time expired?
Set Idle_Time =
Duty_Factor *
Transmit_Duration
Any data to
transmit?