User's Manual
Table Of Contents
- Introduction
- The Integrator’s Task
- Installing the Modem
- Using the Modem Test Jig
- Testing
- Desense
- Application Development
- Message Routing and Migration
- Appendix A - NCL Interface
- Appendix B - Software Development Kit
- SDK Contents
- System Requirements
- SDK Software Architecture
- NCL Application Programmer’s Interface
- Implementation
- Logical Architecture
- Application Interface
- Opening a Session
- Close Session
- Send Data to a Radio Host
- Receive Data From RPM
- Get RPM Status Information
- Set Configuration ITEMS Within the RPM
- Reset RPM
- Register Event Callback Function
- Enable / Disable Events
- Get Error Description
- Register Wakeup Application
- Deregister Wakeup Application
- Switch RPM On/Off
- Send Generic NCL Command To RPM
- Get Software Version
- SCR Application Programmer’s Interface
- A
- Appendix C – Sample programs
- Appendix D - Wavenet Application Loader
- Appendix E - Numeric Conversion Chart
- Appendix F - Specifications
- Appendix H - Glossary
Boomer II User Manual & Integrator’s Guide ___________________________________________________ Testing
BM210012WT27 71 Wavenet Technology
outage. For this reason, you should design the application to allow for
end-user problem determination.
Effective tests provide a systematic, positive acknowledgment from
each of the network components. For example:
Test 1 Is the OEM module able to pass its own self test?
Test 2 Is the OEM module able to communicate with peripherals?
Test 3 Is the OEM module able to communicate with the integrated
modem?
Test 4 Is the modem able to hear the network?
Test 5 Is the modem registered and allowed to operate on the
network?
Test 6 Is the gateway (if present) up and running?
Test 7 Is the host up and running?
OEM Service Depot Repair
When a unit is returned for service, the first requirement is to
determine whether the modem must be sent on to Wavenet for
inspection and/or repair. To set up for this test, you need to have an
evaluation board, a known-good Boomer II OEM modem (for
comparison), a power supply, Wavenet RSUSER software or Wavenet
Modem Test software and an end-to-end test setup. The end-to-end test
can employ either a live network or an over-the-air test involving a
communications monitor that can transmit and receive at the
appropriate frequencies. The objective is to test the suspect modem in a
known-good environment, in which all other components are known to
be operational.