Modem Test Jig ____________________________________________ Boomer II User Manual & Integrator’s Guide
Copyright Wavenet Technology © November 2003 60 BM210012WT37
c. Press down the lock lever.
Note: If the cable has been partially inserted, or out of
alignment, the lock lever will not engage. Should this
occur, remove the cable (see below) and repeat steps
a-c.
Use the following procedure to remove the cable from the FPC
connector.
a. Lift up the lock lever of the FPC connector by flipping it
up with the nail of your thumb or index finger.
b. Remove the cable after the lock is released.
2. Install an antenna to the modem. Use either the on-board SMA
connection and an adapter cable between the modem MMCX
connector and the test jig SMA connector, or connect directly to
the modem itself.
3. Connect the PC serial cable to the DB9 connector marked
“PC”.
4. After making sure the power supply is set with the operating
voltage range of the modem switch the power supply on.
5. Select the DIP switch labelled H-P-ON to the ON position. The
green Power LED on the modem should illuminate.
You are now ready to communicate with the modem using the
PC as a host/terminal. The modem should be able to talk to the
PC by using Wavenet Commander software, or other NCL
protocol software. If the modem is in Hayes compatible mode,
then a terminal program will suffice.
Lock Lever