User's Manual
Table Of Contents
- Introduction
- The Integrator’s Task
- Installing the Modem
- Mounting the Boomer II OEM Modem to Your Device
- Connecting the Data Interface Port
- Selecting & Positioning the Antenna
- Supplying Power
- Using the Modem Test Jig
- Software Development Tools
- Integration Testing
- Appendix A - NCL Interface
- Appendix B – SDK NCL-API and Port Server
- Multisession API
- Application Interface
- _
- Opening a Session
- Close Session
- Send Data to a Radio Host
- Receive Data From RPM
- Get RPM Status Information
- Set Configuration ITEMS Within the RPM
- Reset RPM
- Register Event Callback Function
- Enable / Disable Events
- Get Error Description
- Register Wakeup Application
- Deregister Wakeup Application
- Switch RPM On/Off
- Send Generic NCL Command To RPM
- Get Software Version
- _
- A
- Appendix C – SDK Sample programs
- Appendix D - Application Development
- Appendix E - Message Routing and Migration
- Appendix F – Guide to Desense
- Appendix G - Numeric Conversion Chart
- Appendix H - Specifications
- Appendix I - Glossary
Boomer II User Manual & Integrator’s Guide ________________________________ Appendix A - NCL INTERFACE
BM210012WT37 81 Copyright Wavenet Technology © November 2003
Commands Value Parameters Value Sub-values and Descriptions
S_BAUD ASCII K
Set the baud rate for NCL communications:
BAUD_1200 1200 baud ASCII 0
BAUD_2400 2400 baud ASCII 1
BAUD_4800 4800 baud ASCII 2
BAUD_9600 9600 baud ASCII 3
BAUD_19K2 19200 baud ASCII 4
BAUD_38K4 38400 baud ASCII 5
S_ANTENNA Undefined Select the antenna
ASCII
L..Z
Reserved.
RESET_RPM ASCII 6 Reset RPM.
FLUSH_INBOUND ASCII 1 Flush inbound message queue.
FLUSH_OUTBOUND ASCII 2 Flush outbound message queue.
FLUSH_BOTH ASCII 3 Flush inbound and outbound message queues.
RESET_WARM ASCII 4 Warm start RPM.
RESET_TRANS ASCII 5 Reset to Transparent Mode, if Transparent Mode is supported.
RESET_FULL ASCII 6 Full reset of RPM.
RESET_NCL ASCII 7 Reset NCL interpreter only.
RESET_OFF ASCII 8 Power off the RPM.
RESET_DIAG ASCII A Vendor-specific: Cause DTE to enter diagnostic mode.
ASCII
A..Y, 7..9
Reserved.
VENDOR ASCII Z Vendor-specific command.
Event Report SDUs (EVENT, ASCII B)
Events Value Event Report
Enable
Bit Parameters Value Descriptions
RCV_MSG_
DATA
ASCII A RCV_MSG_DATA_
BIT
$10 Received message
data.
RCV_MSG_
NOTIFICATION
ASCII B RCV_MSG_
NOTIFY_BIT
$08 Received message
notification. True only
if confirmed delivery
mode enabled.
TX_EVENT ASCII C TX_EVENT_BIT $04 Physical-level
transmitter event.
TX_KEYED ASCII 1 Transmitter keyed.
TX_DEKEYED ASCII 2 Transmitter dekeyed.
RX_EVENT ASCII D RX_EVENT_BIT $02 Physical-level receiver
event.
RX_IN_RANGE ASCII 1 RF in range.
RX_OUT_OF_RANGE ASCII 2 RF out of range.
RX_PWR_SAVE_
ENABLED
ASCII 3 Power saving enabled.
RX_PWR_SAVE_
DISABLED
ASCII 4 Power saving disabled.
RX_ACTIVE ASCII 5 Device in active state
on RF channel.
CHAN_DISALLOWED ASCII 6 Device disallowed on
hl