User's Manual
Table Of Contents
- Introduction
- The Integrator’s Task
- Installing the Modem
- Mounting the Boomer˚III OEM Modem to Your Device
- Connecting the Data Interface Port
- Selecting & Positioning the Antenna
- Supplying Power
- Using the Modem Test Jig
- Software Development Tools
- Integration Testing
- Appendix A - NCL Interface
- Appendix B – SDK NCL-API and Port Server
- _
- Logical Architecture
- Application Interface
- Opening a Session
- Close Session
- Send Data to a Radio Host
- Receive Data From RPM
- Get RPM Status Information
- Set Configuration ITEMS Within the RPM
- Reset RPM
- Register Event Callback Function
- Enable / Disable Events
- Get Error Description
- Register Wakeup Application
- Deregister Wakeup Application
- Switch RPM On/Off
- Send Generic NCL Command To RPM
- Get Software Version
- _
- A
- Appendix C – SDK Sample programs
- Appendix D - Application Development
- Appendix E - Message Routing and Migration
- Appendix F – Guide to Desense
- Appendix G - Numeric Conversion Chart
- Appendix H - Specifications
- Appendix I - Glossary
APPENDIX H - Specifications_________________________________ Boomer-III User Manual & Integrator’s Guide
Copyright Wavenet Technology © October 2003 142 BM310012WT04
Appendix H - Specifications
Physical Properties
Weight < 75g
Size (L x W x H) 68mm x 42mm x 8mm
Communication Protocols
Modem to radio network protocol RD-LAP 3.1, 3.2, 3.3 and MDC 3.3
Modem to terminal (e.g. handheld) protocol NCL 1.2
Environmental Conditions
Operating temperature
-30°C to +60°C
Storage temperature
-40°C to 70°C
Relative Humidity 0 to 95%
Ports
Data Interface Port 3V logic serial port,
9600 baud
RF Connector
MMCX female, 50Ω.
Straight connection or right angle
LED Indicators
Power Green flashes when scanning
On, when locked
Off, when the Boomer-III is off
Transmit Red flashes when transmitting
Receive Green flashes when receiving
Power
Voltage 3.8V nominal
(3.4 to 4.8V range)
Transmit < 1.6 A (2.2 A if mismatched antenna)
Receive < 80 mA
Standby < TBD mA
(Add 1.2 mA if LED’s enabled)
Off current consumption 100 µA (nominal)
Transmit Duration 32 ms (minimum)
7 seconds RD-LAP (maximum)
30% (maximum) Duty Cycle
Power Supply Ripple < 15 mV peak to peak