Product Specifications

2.2 Reliability test
TEST CONDITION METHOD REMA
RK
1
High-Temperature Opera
tion
T=50 RH=30%RHFor
240Hr
IEC 60 068-2-2Bb
2
Low-Temperature Opera
tion
T = 0 for 240 hrs
IEC 60 068-2-2Ab
3
High-Temperature Storage
IEC 60 068-2-2Bb
4
Low-Temperature Storage
T = -25,
for 240 hrs
Test in white pattern
IEC 60 068-2-2Ab
5
High Temperature, Hig
h-
H
u
m
i
d
i
t
y O
p
e
r
a
t
i
on
IEC 60 068-2-3CA
6
High Temperature, High-
Humidity Storage
T=40 , RH=90%RH, For
168Hr
T=60 , RH=80%RH, For
240Hr
Test in white pattern
IEC 60 068-2-3CA
7
Temperature Cycle
-25 (30min)~70
(30min)
100 Cycle
Test in white pattern
IEC 60 068-2-14NB
8
Package Vibration
1.04G,Frequency
:
10~500Hz
Direction : X,Y,Z
Duration:1hours
in each
direction
Full packed
for
shipment
9
Package Drop Impact
Drop from height of 122 cm
on
Concrete surface
Drop sequence:1
corner,
3edges,
6face
One drop f
or each.
Full packed for
shipment
10 UV exposure
Resistance 765 W/ for 168
hrs,40
IEC 60068-2-5 Sa
11 Electrostatic
discharge
Machine model:
+/
-250
V,0Ω,200pF
IEC61000-4-2
Actual EMC level to be measured on customer application.
Note1Stay white pattern for storage and non-operation test.
Note2Operation is black/white/red pattern , hold time is 150S.
Note3The function,appearence,opticals should meet the requirements of the test before
and after the test. Note4Keep testing after 2 hours placing at 20 -25.
T=70 RH=40%RH For
240Hr
Test in white pattern
2.13inch e-Paper
www.waveshare.com