Specification
Table Of Contents
7. Point and line standard
Shipment Inspecti
on Standard
Equipment:Electrica
l test fixture, Point gauge
Outline
dimension
2
9.2(H)×59.2 (V)
×1.05(D)
Unit:㎜ Part-A Active area Part-B Border area
Environment
Temperature
Humidity
Illuminance Dista
nce Time
Angle
19℃~25℃
55%±5%RH 800~13
00Lux 300 ㎜ 35Sec
Defet type Inspection met
hod Standard Part-A Part-B
Spot Electric Display D≤0
.25 ㎜ Ignore Ignore
0.25 ㎜<D≤0.4 ㎜ N≤4 Ignore
D>0.4 ㎜ Not Allow Ignore
Display unwork Electri
c Display Not Allow Not Allow Ignore
Display error Electri
c Display Not Allow Not Allow Ignore
Scratch or line
defect(include
dirt)
V
isual/Film card L≤2 ㎜,W≤0.2 ㎜ Ignore Ignore
2.0mm<L≤5.0mm,0.2<
W≤
0.3mm,
N≤2 Ignore
L>5 ㎜,W>0.3 ㎜ Not Allow Ignore
PS Bubble Visual/Film card D≤0.
2mm Ignore Ignore
0.2mm≤D≤0.35mm﹠N≤4 N≤4 Ig
nore
D>0.35 mm Not Allow
Ignore
Corner /Edge
chipping
Visual/Film c
ard X≤6mm,Y≤0.4mm, Do not affect the electrode circuit (Edge
chipping)
X≤1mm,Y≤1mm, Do not affect the elec
trode
circuit(
(Corner
chipping) Ignore
Remark 1.Cannot be
defect & failure cause by appearance defect;
2
.
C
an
n
o
t
b
e
l
ar
g
er size cause by appearance defect;
L
=
l
o
ng W
=wi
d
e
D
=
p
oi
n
t s
ize N=Defects NO
L=long
W=wide D=point size
2.13inch e-Paper
www.waveshare.com
37/39