Data Sheet

www.waveshare.com
2425
[在此处键入]
11. Reliability test
TEST ITEMS
CONDITION
METHOD
REMARK
1
High-Temperature
Operation
T = 50,30% for 240 hrs
IEC 60 068-2-2Bp
2
Low-Temperature
Operation
T = 0 for 240 hrs
IEC 60 068-2-2Ab
3
High-Temperature Storage
T = +70, 23% for 240 hrs
Test in white pattern
IEC 60 068-2-2Bp
4
Low-Temperature Storage
T = -25 for 240 hrs
Test in white pattern
IEC 60 068-2-2Ab
5
High Temperature, High-
Humidity Operation
T=+40,RH=90%for168hrs
IEC 60 068-2-3CA
6
High Temperature, High-
Humidity Storage
T=+60,RH=80%for240hrs
Test in white pattern
IEC 60 068-2-3CA
7
Temperature Cycle
[-2530mins]
[+70 30mins]
,70cycles
Test in white pattern
IEC 60
068-2-14NB
8
UV exposure Resistance
765 W/m
2
for 168 hrs,40
IEC 60 068-2-5 Sa
9
Electrostatic discharge
Air-mode:+/-8kV,
Contact-mode:+/-6kV,
330Ω,150pF
IEC61000-4-2
10
Package Vibration
1.04G,Frequency : 10~500Hz
Direction : X,Y,Z
Duration:1hours in each direction
Full packed for
shipment
11
Package Drop Impact
Drop from height of 122 cm on
Concrete surface
Drop sequence:1 corner, 3edges,
6face
One drop for each.
Full packed for
shipment
12
Altitude test Operation
700hPa ( =3000 m ),48Hr
13
Altitude test Storage
260hPa ( =10000 m ),48Hr
Test in white pattern
14
Stylus Tapping
POLYACETAL
Pen: Top
R:0.8mm
Load: 300gf
Speed: 30times/min
Total 13,500times,
Test should be
done with a
bezel
Pass criteria
no glass
breakage or
damage to
microcapsules
Actual EMC level to be measured on customer application.