Datasheet

(3) Power OFF (PWR) (R02H)
Action W/R C/D D7 D6 D5 D4 D3 D2 D1 D0
Turning OFF the power 0 0 0 0 0 0 0 0 1 0
After the Power Off command, the driver will power off following the Power Off Sequence. This command will turn off charge
pump, T-con, source driver, gate driver, VCOM, and temperature sensor, but register data will be kept until VDD becomes OFF.
Source Driver output and Vcom will remain as previous condition, which may have 2 condition: 0V or floating.
(4) Power off sequence setting (PFS) (R03H)
Action W/R C/D D7 D6 D5 D4 D3 D2 D1 D0
Setting Power OFF sequence
0
0 0 0 0 0 0 0 1 1
0 1 - - T_VDS_OFF[1:0] - - - -
T_VDS_OFF[1:0]: Power OFF Sequence of VDH and VDL.
00b: 1frame (Default) 01b: 2 frames 10b: 3frames 11b:4 frame
(5) Power ON (PON) (R04H)
Action W/R C/D D7 D6 D5 D4 D3 D2 D1 D0
Turning ON the Power 0 0 0 0 0 0 0 1 0 0
After the Power ON command, the driver will be powered ON following the Power ON Sequence. Refer to the Power ON
Sequence section. In the sequence, temperature sensor will be activated for one time sensing before enabling booster.
(6) Power ON Measure (PMES) (R05H)
Action W/R C/D D7 D6 D5 D4 D3 D2 D1 D0
0 0 0 0 0 0 0 1 0 1
This command enables the internal bandgap, which will be cleared by the next POF.
(7) Booster Soft Start (BTST) (R06H)
Action
W/
R
C/
D
D7 D6 D5 D4 D3 D2 D1 D0
Starting
data
transmissio
n
0 0 0 0 0 0 0 1 1 0
0 1
BT_PHA
7
BT_PHA
6
BT_PHA
5
BT_PHA
4
BT_PHA
3
BT_PHA
2
BT_PHA
1
BT_PHA
0
0 1
BT_PHB
7
BT_PHB
6
BT_PHB
5
BT_PHB
4
BT_PHB
3
BT_PHB
2
BT_PHB
1
BT_PHB
0
0 1 - -
BT_PHC
5
BT_PHC
4
BT_PHC
3
BT_PHC
2
BT_PHC
1
BT_PHC
0
BTPHA[7:6]: Soft start period of phase A.
00b: 10mS 01b: 20mS 10b: 30mS 11b: 40mS
BTPHA[5:3]: Driving strength of phase A
000b: strength 1 001b: strength 2 010b: strength 3 011b: strength 4
100b: strength 5 101b: strength 6 110b: strength 7 111b: strength 8 (strongest)
BTPHA[2:0]: Minimum OFF time setting of GDR in phase B
000b: 0.27uS 001b: 0.34uS 010b: 0.40uS 011b: 0.54uS
4.2" e-Paper
www.waveshare.com
1445