AMV: Analog signal
0: Get Vcom value with the VV command (R81h) (default)
1: Get Vcom value in analog signal. (External analog to digital converter)
AMVE: Auto Measure Vcom Enable (/Disable)
0: No effect
1: Trigger auto Vcom sensing.
(29) Vcom Value (VV) (R81H)
Action W/R C/D D7 D6 D5 D4 D3 D2 D1 D0
Automatically measure Vcom
0 0
1 0 0 0 0 0 0 1
1 1 - - VV[5:0]
This command gets the Vcom value.
VV[5:0]: Vcom Value Output
VV[5:0] Vcom value
00 0000b -0.10 V
00 0001b -0.15 V
00 0010b -0.20 V
: :
11 1010b -3.00 V
(30) VCM_DC Setting (VDCS) (R82H)
Action W/R C/D D7 D6 D5 D4 D3 D2 D1 D0
Set VCM_DC
0 0
1 0 0 0 0 0 1 0
0 1 - - VDCS[5:0]
This command sets VCOM_DC value
VDCS[5:0]: VCOM_DC Setting
VDCS[5:0] Vcom value
00 0000b -0.10 V (default)
00 0001b -0.15 V
00 0010b -0.20 V
: :
11 1010b -3.00 V
(31) Partial Window(PTL) (R90H)
Action W/R C/D D7 D6 D5 D4 D3 D2 D1 D0
Set Partial Window
0 0 1 0 0 1 0 0 0 0
0 1 - - - - - - - HRST[8]
0 1 HRST[7:3] 0 0 0
0 1 - - - - - - - HRED[8]