Datasheet

70cycles,
Test in white
pattern
let temperature rise to 70. After 30min, temperature
will be adjusted to 70 and storage period is 30
minutes. After 30 minutes, it needs 30min to let
temperature rise to -25. One temperature cycle
(2hrs) is complete.
2. Temperature cycle repeats 70 times.
3. When 70 cycles finished, the samples will be taken out
from experiment chamber and set aside a few minutes.
As EPDs return to room temperature, tests will
observe the appearance, and test electrical and optical
performance based on standard # IEC 60 068-2-14NB.
and optical
performance
standards.
8
UV exposure
Resistance
765 W/m
2
for 168
hrs,40
Standard # IEC 60 068-2-5 Sa
9
Electrostatic
discharge
Machine model:
+/-250V,
0Ω,200pF
Standard # IEC61000-4-2
10
Package
Vibration
1.04G,Frequency :
10~500Hz
Direction : X,Y,Z
Duration:1hours
in each direction
Full packed for shipment
11
Package Drop
Impact
Drop from height
of 122 cm on
Concrete surface
Drop sequence:1
corner, 3edges,
6face
One drop for
each.
Full packed for shipment
Actual EMC level to be measured on customer application.
Note: (1) The protective film must be removed before temperature test.
(2) In order to make sure the display module can provide the best display quality, the update should be made after putting the
display module in stable temperature environment for 15 mins.
4.2" e-Paper
www.waveshare.com
4345