11. Reliability test
TEST CONDITION METHOD REMARK
1
High-Temperatu
re Operation
T =40,
RH=35% for 240
hrs
When the experimental cycle finished, the EPD samples
will be taken out from the high
temperature environmental chamber and set aside for a few
minutes. As EPDs return to room temperature, testers will
observe the appearance, and test electrical and optical
performance based on standard # IEC 60068-2-2Bp.
When experiment
finished, the EPD
must meet electrical
and optical
performance
standards.
2
Low-Temperatu
re Operation
T = 0 for 240
hrs
When the experimental cycle finished, the EPD samples
will be taken out from the low
temperature environmental chamber and set aside for a few
minutes. As EPDs return room temperature, testers will
observe the appearance, and test electrical and optical
performance based on standard # IEC 60068-2-2Ab.
When experiment
finished, the EPD
must meet electrical
and optical
performance
standards.
3
High-Temperatu
re Storage
T = +60,
RH=35%
for 240 hrs
Test in white
pattern
When the experimental cycle finished, the EPD samples
will be taken out from the high
temperature environmental chamber and set aside for a few
minutes. As EPDs return to room temperature, testers will
observe the appearance, and test electrical and optical
performance based on standard # IEC 60068-2-2Bp.
When experiment
finished, the EPD
must meet electrical
and optical
performance
standards.
4
Low-Temperatu
re Storage
T = -25
for 240 hrs
Test in white
pattern
When the experimental cycle finished, the EPD samples
will be taken out from the low
temperature environmental chamber and set aside for a few
minutes. As EPDs return to room temperature, testers will
observe the appearance, and test electrical and optical
performance based on standard # IEC 60068-2-2Ab.
When experiment
finished, the EPD
must meet electrical
and optical
performance
standards.
5
High
Temperature,
High-
Humidity
Operation
T=+40,
RH=80%
for 240 hrs
When the experimental cycle finished, the EPD samples
will be taken out from the environmental chamber and set
aside for a few minutes. As EPDs return to room
temperature, testers will observe the appearance, and test
electrical and optical performance based on standard # IEC
60068-2-3CA.
When experiment
finished, the EPD
must meet electrical
and optical
performance
standards.
6
High
Temperature,
High-
Humidity
Storage
T=+50,
RH=80%
for 240 hrs
Test in white
pattern
When the experimental cycle finished, the EPD samples
will be taken out from the environmental chamber and set
aside for a few minutes. As EPDs return to room
temperature, testers will observe the appearance, and test
electrical and optical performance based on standard # IEC
60068-2-3CA.
When experiment
finished, the EPD
must meet electrical
performance
standards.
7
Temperature
Cycle
[-25 30mins]
[+60,RH=35%
30mins], 50cycles
Test in white
1. Samples are put in the Temp & Humid. Environmental
Chamber. Temperature cycle starts with -25 , storage
period 30 minutes. After 30 minutes, it needs 30min to
let temperature rise to 60. After 30min, temperature
When experiment
finished, the EPD
must meet electrical
and optical
.
2.7" e-Paper (B)